EasyManua.ls Logo

Ferroli ATLAS D 30 K 100 UNIT User Manual

Ferroli ATLAS D 30 K 100 UNIT
88 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
cod. 3540S75 — Rev. 01 - 03/2015
ATLAS D 30 K 100 UNIT
IT -
ISTRUZIONE PER L’USO L'INSTALLAZIONE E LA MANUTENZIONE
ES -
INSTRUCCIONES DE USO, INSTALACIÓN Y MANTENIMIENTO
TR -
KULLANMA, KURULUM VE BAKøM TALIMATLARø
EN -
INSTRUCTIONS FOR USE, INSTALLATION AND MAINTENANCE
FR -
INSTRUCTIONS D'UTILISATION, D'INSTALLATION ET D'ENTRETIEN
GR -
ȅǻǾīǴǼȈ ȋȇdzȈǾȈ, ǼīȀǹȉDZȈȉǹȈǾȈ Ȁǹǿ ȈȊȃȉdzȇǾȈǾȈ
NL -
AANWIJZINGEN VOOR GEBRUIK, INSTALLATIE EN ONDERHOUD
RU -
ɊɍɄɈȼɈȾɋɌȼɈ ɉɈ ɗɄɋɉɅɍȺɌȺɐɂɂ, ɆɈɇɌȺɀɍ ɂ ɌȿɏɈȻɋɅɍɀɂȼȺɇɂɘ
Question and Answer IconNeed help?

Do you have a question about the Ferroli ATLAS D 30 K 100 UNIT and is the answer not in the manual?

Ferroli ATLAS D 30 K 100 UNIT Specifications

General IconGeneral
CategoryBoiler
Fuel TypeDiesel
Nominal heat output30 kW
Max working pressure3 bar
Protection ratingIPX4D
TypeFloor standing
Electrical connection230 V

Summary

1. GENERAL WARNINGS

General Warnings

Read and follow all instructions. Ensure professional installation and maintenance.

2. OPERATING INSTRUCTIONS

2.2 Control panel

Details the components of the boiler's control panel and their functions.

2.4 Adjustments

Compensation curve and curve offset

How to adjust compensation curves and their parallel offset for heating temperature control.

3. INSTALLATION

3.1 General Instructions

Mandatory installation by qualified personnel following all instructions and regulations.

3.3 Plumbing connections

Guidance on connecting plumbing systems, including safety valve and shut-off valves.

4. SERVICE AND MAINTENANCE

4.1 Adjustments

Details on performing adjustments and commissioning, including TEST mode activation.

TEST mode activation

How to activate and deactivate the TEST mode for boiler diagnostics.

3.5 Electrical connections

Details on connecting the boiler to the electrical grid, earthing, and safety precautions.

Burner adjustment

Burner adjustment

Factory settings for the burner and how to adjust power, nozzle, head, and air.

4.2 Commissioning

Lighting

Step-by-step procedure for starting the burner and the boiler.

4.3 Maintenance

Periodical check

Annual maintenance checks recommended for optimal boiler operation.

4.4 Troubleshooting

Diagnostics

Explanation of the boiler's self-diagnosis system and fault code indications.

5.4 Wiring diagram

Wiring diagram

Schematic diagram illustrating the boiler's electrical connections and component layout.