EasyManua.ls Logo

Ferroli ATLAS D 30 SI UNIT - User Manual

Ferroli ATLAS D 30 SI UNIT
88 pages
Go to English
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
cod. 3540S516 — Rev. 01 - 03/2015
ATLAS D 30 SI UNIT
IT -
ISTRUZIONE PER L’USO L'INSTALLAZIONE E LA MANUTENZIONE
ES -
INSTRUCCIONES DE USO, INSTALACIÓN Y MANTENIMIENTO
TR -
KULLANMA, KURULUM VE BAKøM TALIMATLARø
EN -
INSTRUCTIONS FOR USE, INSTALLATION AND MAINTENANCE
FR -
INSTRUCTIONS D'UTILISATION, D'INSTALLATION ET D'ENTRETIEN
GR -
ȅǻǾīǴǼȈ ȋȇdzȈǾȈ, ǼīȀǹȉDZȈȉǹȈǾȈ Ȁǹǿ ȈȊȃȉdzȇǾȈǾȈ
NL -
AANWIJZINGEN VOOR GEBRUIK, INSTALLATIE EN ONDERHOUD
RU -
ɊɍɄɈȼɈȾɋɌȼɈ ɉɈ ɗɄɋɉɅɍȺɌȺɐɂɂ, ɆɈɇɌȺɀɍ ɂ ɌȿɏɈȻɋɅɍɀɂȼȺɇɂɘ
6

Questions and Answers

  • M
    michaeldavisAug 18, 2025
    What to do if my Ferroli Boiler shows incorrect system water pressure is too high?
    • M
      Mark AndersonAug 18, 2025
      If your Ferroli Boiler indicates incorrect system water pressure is too high, check the system. Also check the safety valve and the expansion tank.
  • G
    gregorykimberlyAug 23, 2025
    What to do if my Ferroli Boiler activates overtemperature protection?
    • Q
      qhowardAug 23, 2025
      If the overtemperature protection activates in your Ferroli Boiler, it could be due to a damaged heating sensor, no water circulation, or air in the system. Check the heating sensor's positioning and operation, inspect the circulating pump, and vent the system to resolve these issues.
  • M
    Mary SmithAug 26, 2025
    Why is my Ferroli Boiler showing a flame present signal when the burner is off?
    • R
      Roberta BrownAug 26, 2025
      If your Ferroli Boiler shows a flame present signal when the burner is off, it could be due to a photoresistance short circuit or extraneous light striking the photoresistance. Replace the photoresistance or eliminate the extraneous light source to fix this.
  • V
    Vincent RodriguezAug 27, 2025
    What does it mean if my Ferroli Boiler displays 'Delivery sensor 1 fault'?
    • A
      Alexandria HernandezAug 28, 2025
      If your Ferroli Boiler displays a 'Delivery sensor 1 fault', it could indicate a damaged sensor or wiring issues. Check the wiring or replace the sensor.
  • C
    Crystal PeckAug 29, 2025
    What does it mean if my Ferroli ATLAS D 30 SI UNIT displays 'Delivery sensor 2 fault'?
    • E
      Eric GriffithAug 30, 2025
      If your Ferroli Boiler displays a 'Delivery sensor 2 fault', it could indicate a damaged sensor or wiring issues. Check the wiring or replace the sensor.
  • R
    Robert AndrewsSep 1, 2025
    What should I do if my Ferroli Boiler displays 'External probe fault'?
    • C
      Charles KingSep 1, 2025
      If your Ferroli Boiler displays an 'External probe fault', the probe might be damaged, the wiring could be shorted, or the probe might be disconnected after activating the sliding temperature. Check the wiring, replace the sensor if necessary, reconnect the external probe, or disable the sliding temperature.
  • J
    jwarrenSep 3, 2025
    What to do if my Ferroli ATLAS D 30 SI UNIT shows 'Heating sensor fault'?
    • J
      Johnathan YoderSep 3, 2025
      If your Ferroli Boiler displays a 'Heating sensor fault', the sensor is likely damaged and needs to be replaced.
  • M
    melissareyesSep 5, 2025
    What does it mean if my Ferroli ATLAS D 30 SI UNIT Boiler displays 'Card parameter fault'?
    • A
      Andrew SmithSep 6, 2025
      If your Ferroli Boiler displays a 'Card parameter fault', it indicates a wrong card parameter setting. Check the card parameter and modify it if necessary.
  • J
    Jonathan KramerSep 8, 2025
    What should I do if my Ferroli ATLAS D 30 SI UNIT displays 'System water pressure sensor fault'?
    • P
      Patrick LarsonSep 8, 2025
      If your Ferroli Boiler displays a 'System water pressure sensor fault', it is likely due to disconnected wiring. Check the wiring.
  • J
    Jillian ParkSep 10, 2025
    What to do if my Ferroli Boiler shows 'Supply voltage under 170V'?
    • D
      Dr. Lauren ClarkSep 12, 2025
      If your Ferroli Boiler indicates a 'Supply voltage under 170V', it suggests there is an electric mains trouble. Check the electrical system.

Summary

General Warnings

General Safety Instructions

Provides critical safety instructions for installation, maintenance, and operation.

Operating Instructions

Introduction, Control Panel, and Indicators

Introduction, control panel layout, and operational indicators.

Boiler Lighting and Shutdown

Instructions on how to start up and shut down the boiler.

Adjustments Overview

Overview of boiler adjustments including temperature, modes, and curves.

Summer;Winter Switchover

How to switch between summer and winter operating modes.

Heating Temperature Adjustment

Instructions for adjusting the system water temperature.

Compensation Curve Settings

Explanation of compensation curve settings for weather-dependent control.

Installation

General Installation Instructions

General guidelines and requirements for boiler installation.

Place of Installation

Specifies the required location and ventilation for boiler installation.

Plumbing Connections

Details on connecting the boiler to the heating and hot water systems.

Burner Connection

Instructions for connecting the burner, including flexible pipes and filter.

Coaxial Pipe Connections

Guidance on connecting the boiler using coaxial flue pipes.

Separate Pipe Connections

Guidance on connecting the boiler using separate flue pipes.

Service and Maintenance

Adjustments

Procedures for activating TEST mode and adjusting burner settings.

Pump Pressure Adjustment

Instructions for adjusting the pump pressure for optimal operation.

Burner Head and Air Shutter Adjustment

How to adjust the burner head and air shutter for optimal performance.

Electrode and Baffle Positioning

Checking electrode and baffle positioning after nozzle replacement.

Commissioning

Checks to be performed before first lighting and after maintenance.

Checks During Operation

Ensuring proper operation and efficiency of the boiler during use.

Periodic Maintenance

Periodic checks required for long-term correct operation of the unit.

Troubleshooting

Diagnostics system and troubleshooting guide for boiler faults.

Technical Data and Characteristics

Dimensions, Connections, and Components

Diagrams and list of main components and connections of the boiler.

Pressure Loss

Graph showing circulating pump head/pressure loss characteristics.

Technical Data Table

Table detailing technical specifications and performance data of the boiler.

Wiring Diagram

Declaration of Conformity

Ferroli ATLAS D 30 SI UNIT Specifications

General IconGeneral
TypeCondensing
Fuel TypeNatural Gas / LPG
Thermal power30 kW
Nominal heat output30 kW
Maximum working pressure3 bar
Weight34 kg
Electrical connection230V / 50Hz
IgnitionElectronic
FuelNatural Gas, LPG
Water content4.5 liters
MountingWall-mounted

Related product manuals