What does it mean if my Ferroli Boiler shows Faulty mains frequency?
- LledavidSep 9, 2025
If your Ferroli Boiler shows a faulty mains frequency, it indicates electric mains trouble. Check the electrical system.
What does it mean if my Ferroli Boiler shows Faulty mains frequency?
If your Ferroli Boiler shows a faulty mains frequency, it indicates electric mains trouble. Check the electrical system.
What to do if Ferroli Boiler activates overtemperature protection?
If your Ferroli Boiler activates overtemperature protection, it could be due to: * A damaged heating sensor: Check the correct positioning and operation of the heating sensor. * No water circulation in the system: Check the circulating pump. * Air in the system: Vent the system.
What to do if Ferroli Boiler has no flame after the ignition phase?
If your Ferroli Boiler shows no flame after the ignition phase, the possible causes are: * Low pressure in the gas system: Check the gas pressure. * Incorrect burner minimum pressure setting: Check the pressures.
What to do if my Ferroli Boiler signals flame present with burner off?
If your Ferroli Boiler signals flame present even when the burner is off, it could be due to: * Electrode fault: Check the ionization electrode wiring. * Card fault: Check the card.
What to do if my Ferroli Boiler has Incorrect system water pressure?
If your Ferroli Boiler shows incorrect system water pressure, it might be caused by: * Pressure too low: Fill the system. * Water pressure switch damaged or not connected: Check the sensor.
What to do if Ferroli Boiler has a Gas valve fault?
If your Ferroli Boiler reports a gas valve fault, it could be due to: * Disconnected wiring: Check the wiring. * Faulty gas valve: Check the gas valve and replace it if necessary.
How to troubleshoot Heating sensor fault in Ferroli Boiler?
If your Ferroli Boiler displays a heating sensor fault, it may be caused by sensor damage. Replace the sensor.
What to do if my Ferroli Boiler reports External probe fault?
If your Ferroli Boiler reports an external probe fault, it could be due to: * Probe damaged or wiring shorted: Check the wiring or replace the sensor. * Probe disconnected after activating the sliding temperature: Reconnect the external probe or disable the sliding temperature.
What to do if Ferroli Boiler shows Supply voltage under 180V?
If your Ferroli Boiler indicates a supply voltage under 180V, it is due to electric mains trouble. Check the electrical system.
How to troubleshoot Flow sensor 2 fault in Ferroli Boiler?
If your Ferroli Boiler displays a Flow sensor 2 fault, it may be caused by sensor damage. Check the wiring or replace the sensor.