What does it mean if my Ferroli Boiler shows Faulty mains frequency?
- LledavidSep 9, 2025
If your Ferroli Boiler shows a faulty mains frequency, it indicates electric mains trouble. Check the electrical system.
What does it mean if my Ferroli Boiler shows Faulty mains frequency?
If your Ferroli Boiler shows a faulty mains frequency, it indicates electric mains trouble. Check the electrical system.
What to do if Ferroli Boiler activates overtemperature protection?
If your Ferroli Boiler activates overtemperature protection, it could be due to: * A damaged heating sensor: Check the correct positioning and operation of the heating sensor. * No water circulation in the system: Check the circulating pump. * Air in the system: Vent the system.
What to do if Ferroli Boiler has no flame after the ignition phase?
If your Ferroli Boiler shows no flame after the ignition phase, the possible causes are: * Low pressure in the gas system: Check the gas pressure. * Incorrect burner minimum pressure setting: Check the pressures.
What to do if my Ferroli Boiler signals flame present with burner off?
If your Ferroli Boiler signals flame present even when the burner is off, it could be due to: * Electrode fault: Check the ionization electrode wiring. * Card fault: Check the card.
What to do if my Ferroli Boiler has Incorrect system water pressure?
If your Ferroli Boiler shows incorrect system water pressure, it might be caused by: * Pressure too low: Fill the system. * Water pressure switch damaged or not connected: Check the sensor.
What to do if Ferroli Boiler has a Gas valve fault?
If your Ferroli Boiler reports a gas valve fault, it could be due to: * Disconnected wiring: Check the wiring. * Faulty gas valve: Check the gas valve and replace it if necessary.
How to troubleshoot Heating sensor fault in Ferroli Boiler?
If your Ferroli Boiler displays a heating sensor fault, it may be caused by sensor damage. Replace the sensor.
What to do if my Ferroli Boiler reports External probe fault?
If your Ferroli Boiler reports an external probe fault, it could be due to: * Probe damaged or wiring shorted: Check the wiring or replace the sensor. * Probe disconnected after activating the sliding temperature: Reconnect the external probe or disable the sliding temperature.
What to do if Ferroli Boiler shows Supply voltage under 180V?
If your Ferroli Boiler indicates a supply voltage under 180V, it is due to electric mains trouble. Check the electrical system.
How to troubleshoot Flow sensor 2 fault in Ferroli Boiler?
If your Ferroli Boiler displays a Flow sensor 2 fault, it may be caused by sensor damage. Check the wiring or replace the sensor.
Brand | Ferroli |
---|---|
Model | DIVA D C24 |
Category | Portable Generator |
Language | English |
Crucial warnings regarding installation, maintenance, use, and potential hazards to prevent injury or damage.
Explains the meaning of CAUTION symbols and important notices used in the manual.
Overview of the boiler, its control panel layout, buttons, display, and operational indicators.
Procedures for turning the boiler on/off, frost protection, and switching between Summer/Winter modes.
Details setting heating/DHW temperatures, room temp, ECO/COMFORT, Sliding Temperature, and compensation curves.
Explains how adjustments are managed when using the optional remote timer control.
Instructions for checking and adjusting system water pressure using the filling knob.
Guide on how to drain the heating system water using the safety valve drain faucet.
Essential rules for qualified personnel, proper workmanship, and adherence to regulations for boiler installation.
Criteria for selecting an appropriate installation site, considering ventilation, clearance, and environmental factors.
Details on making plumbing connections, safety valve outlet, water treatment, and antifreeze usage.
Specific instructions for connecting the gas supply, ensuring safety and compliance with regulations.
Critical information on electrical connections, grounding, cable replacement, and precautions for room thermostats.
Requirements for installing air and fume ducts, including sizing, vertical sections, and safety devices.
Detailed steps for converting the boiler between natural gas and LPG, including parameter settings and component replacement.
Step-by-step guide for calibrating the gas valve and checking gas pressures at different operating ranges.
Instructions on how to activate and use the boiler's test mode for performance checks and adjustments.
Procedures for adjusting heating power and configuring various boiler parameters via the configuration menu.
How to access the Service Menu, Transparent Parameters (tS), and Information Menu (In) for advanced settings.
Details the range and function of transparent parameters for fine-tuning boiler operation.
Accessing the Information Menu to view sensor readings, burner status, and other operational data.
Procedures for accessing the fault history and resetting recorded errors.
Step-by-step guide for the initial setup, checks, and testing of the boiler after installation.
Details annual inspection points for safety devices, fume circuit efficiency, burner cleanliness, and electrode positioning.
Explains how the boiler detects faults, displays error codes, and the procedure for restoring operation.
Detailed list of fault codes, their possible causes, and recommended solutions for various components and system issues.
Illustrates physical dimensions, connection ports, wall mounting specs, and main internal components.
Visual representation of the hydraulic system and a comprehensive table of product specifications and operating parameters.
Includes performance curves, pump characteristics, and the complete electrical wiring schematic.