8
DIMENSIONAL AND PHYSICAL DATA
Operating limits
35
-2
-20
5
40 60
30
55
30
43
-2
-20
5
5040 60
Leaving water temperature °C
Leaving water temperature °C
With electrical heaters
or bolier
With electrical heaters
or bolier
Outside temperature °C
Outside temperature °C
DHW MODEHEATING MODE
Leaving water temperature °C
Outside temperature °C
20
46
-5
510 25
10
COOLING MODE
NOTE FOR DHW MODE: leaving water temperature is the temperature of the water produced by the unit and not the DHW temperature available to the user; the DHW
temperature is in fact a function of this parameter and of the coil surface of the DHW boiler.
Available static pressure
Watel ow rate [l/h]
Available static pressure [kPa]
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 2200 2300 2400 2500
Mod. 16
Mod. 08