We recommend cleaning the main filter com
pletely if severely clogged:
Set the suction power adjuster [1-8] to the
maximum setting.
Cover the end of the nozzle or suction hose
with your hand for 10 seconds.
Turn the switch
[1-9] to the AC symbol.
When the CT-VS closing slide is used
(order
no.: 497926), the filter can be
cleaned fully without removing the
connected electric power tools.
In intensive applications that generate adherent
dust,
it may be necessary to clean the filter ele
ment mechanically under certain circumstan
ces (extract). Wear a dust mask!
8.6 Applying the brake
Folding out the brake lever [1-13]
prevents the
mobile dust extractor from rolling. To achieve
this, lift the front end of the mobile dust extrac
tor slightly and push the brake lever down
wards until it latches into place. Push the lev
er [1-12]
again to release.
9 Working
9.1 Handling
Hose store: after finisching work, you can feed
the suction hose through the recess [4-2]
and
place it in the hose store.
SysDoc Systainer attachment system: a Sys
tainer
can be attached to the storeage area via
the four slides ore the T-Loc [4-1]
.
4
C
TM 36 E
AC
3/$1
(
;
CTM 36 E AC
4-1 4-1
4-2
9.2 Extracting dry materials
CAUTION
Hazardous dust
Damage to the respiratory passage
Use a filter or disposal bag when extracting
hazardous materials!
Do not use the machine if the volumetric
flow monitoring function is inactive.
Observe the following when extracting dust
generated by operating electric power tools:
If the exhaust air is discharged back into the
room,
the air renewal rate L within the room
must
be sufficient. The volume of air dis
charged back into the room must not exceed
50% of the fresh air volume flow (room volume
V
R
x air renewal rate L
W
). Observe all the rele
vant regional regulations.
Remember: A moist main filter clogs more
quickly when extracting dry materials. There
fore, dry the main filter before extracting dust
or replace the damp filter with a dry one.
9.3 Extracting fluids
WARNING
Risk of injury
Do not evacuate combustible liquids!
The main filter shall only be used for
extracting dry materials.
Before extracting fluids, remove the filter bag
(see chapter 10.1 ). We recommend using a
special wet filter.
The dust extractor stops automatically when
the maximum level is reached.
CAUTION
Escaping foam and fluids
Switch off the machine immediately and
empty the dust container.
9.4 Special features of the CT 36 E AC- LHS
To use the mobile dust extractor in combination
with the
PLANEX:
Use kink-resistant suction hose D 36 mm x
3.5 m-AS.
Use a special suction sleeve for connecting
the PLANEX
.