1
2
3
7
ENS-CT 26/36/48
7-1
Insert a new disposal bag (ENS-CT26/36) on
the inlet nozzle of the container and lock in
position.
Important:
The lateral openings on the dis
posal bag must be positioned inside the
container. Make sure that the bolt engages.
Place the disposal bag over the edge of the
container.
Make sure that the contacts [7-1] are
free.
Replace the top section [2-1]
and close the
locking clips [2-2].
Removing the disposal bag [8]
Open the locking clips [2-2] and remove the
top section of the machine [2-1]
.
1
2
3
8
Close the disposal bag.
Remove the disposal bag.
Dispose of the used disposal bag in accord
ance with statutory regulations.
Clean the dust container [2-3].
Replace the top section [2-1] and close the
locking clips
[2-2].
10.3 Changing the main filter
NOTE
Motor damage
Never operate the extractor without a main
filter fitted as the motor may become dam
aged.
Open the locking clips [2-2]
and remove the
top section of the machine [2-1].
Turn the top section of the machine so that
the main filter is facing upwards (Fig.[9]).
Fold over the lever [9-3] and remove the re
tainer [9-2]
.
Remove the used main filter [9-1]
and re
place with a new one.
Dispose of the used main filter in accord
ance with statutory regulations.