3
Weights Capacities and Measurements
Weights and Capacities & Measurements; 3 liter and 1 gallon brewers
Brewer Height Width Depth
Empty
Weight
Filled
Weight
Total Weight-
Brewer &
Filled Dispenser
Shipping
Weight
Shipping Dimensions
CBS-2131
3 liter
21 ⅜”
54.3cm
11 ¾”
30.3cm
20 ⅜”
51.8cm
29 lb
13.1kg
50 lb
22.7 kg
61.2lb
27.8 kg
36.3 lb
16.5 kg
22 ¾”x 16 5/8” x 22 7/8”
57.8 x42.3x58.1cm
CBS-2131
I gallon
23 ⅜”
59.4cm
11 ¾”
30.3cm
20 ⅜”
51.8cm
29 lb
13.1kg
50 lb
22.7 kg
63lb
28.6 kg
36.3 lb
16.5 kg
22 ¾”x 16 5/8” x 22 7/8”
57.8 x42.3x58.1cm
CBS-2132
3 liter
21 ⅜”
54.3cm
19 ¾”
50.2cm
20 ⅜”
51.8cm
42.6lb
19.3 kg
87.6 lb
39.7kg
110lb
49.9 kg
49.4 lb
22.4 kg
24½” x 22⅞” x 23”
62.2 x 58.1 x 58.4cm
CBS-2132
I gallon
23 ⅜”
59.4cm
19 ¾”
50.2cm
20 ⅜”
51.8cm
42.6lb
19.3 kg
87.6 lb
39.7 kg
114 lb
51.7 kg
49.4 lb
22.4 kg
24½” x 22⅞” x 23”
62.2 x 58.1 x 58.4cm
Electrical Configuration and Brewing Efficiency
.
Electrical Configurations- CBS-2132—3 liter version
Configuration
Code
Heater
Configuration
Bypass
Voltage
Phase
Wires
Electrical
Connection
KW
Maximum
Amp Draw
Gallon/Hour
(3 liters per batch)
E213201 2 X 2.3 kW NO 200-240 1 2+G Terminal Block 3.3 – 4.7 16.5 - 19.7 11.5 gal/43.5 lit
E213202 2 X 3.0 kW NO 200-240 1 2+G Terminal Block 4.2 – 6.1 21.3—25.5 14.0 gal/53 lit
.
Electrical Configurations- CBS-2131—1 gallon airpot version
Configuration
Code
Heater
Configuration
Bypass
Voltage
Phase
Wires
Electrical
Connection
KW
Maximum
Amp Draw
Gallon/Hour
(1 gallon per batch)
E213102 1 X 2.3 kW NO
100 - 120
1 2+G NEMA 5-20P 1.7
2.4 16.5 - 19.7 5.8
al/22 lit
E213112 1 X 2.3 kW YES
100 - 120
1 2+G NEMA 5-20P 1.7 – 2.4 16.5 - 19.7 5.8 gal/22 lit
E213106 1 X 2.3 kW NO
200 - 240
1 2+G Cord/No Plug 1.7 – 2.4 8.5 – 10.1 5.8 gal/22 lit
E213116 1 X 2.3 kW YES
200 - 240
1 2+G Cord/No Plug 1.7 – 2.4 8.5 – 10.1 5.8 gal/22 lit
E213108 1 X 3.0 kW NO
200 - 240
1 2+G Cord/No Plug 2.2 – 3.1 10.9 – 13.0 7.7 gal/29.1 lit
E213118 1 X 3.0 kW YES
200 - 240
1 2+G Cord/No Plug 2.2 – 3.1 10.9 – 13.0 7.7 gal/29.1 lit
.
Electrical Configurations- CBS-2132—1 gallon airpot version
Configuration
Code
Heater
Configuration
Bypass
Voltage
Phase
Wires
Electrical
Connection
KW
Maximum
Amp Draw
Gallon/Hour
(1 gallon per batch)
E213203 2 X 3.0 kW NO 200-240 1 2+G Terminal Block 4.2 – 6.1 21.3—25.5 14.0 gal/53 lit
E213213 2 X 3.0 kW YES 200-240 1 2+G Terminal Block 4.2 – 6.1 21.3—25.5 14.0 gal/53 lit
Designs, materials, specifications, physical dimensions, firmware and software protocol for equipment or replacement parts are subject to review and change by FETCO without notice
Electrical Configurations- CBS-2131—3 liter version
Configuration
Code
Heater
Configuration
Bypass
Voltage
Phase
Wires
Electrical
Connection
KW
Maximum Amp
Draw
Gallon/Hour
(3 liters per batch)
E213103 1 X 1.5 kW NO
100 - 120
1 2+G NEMA 5-15P 1.1
1.6 10.9
13.0 3.9
al/14.8 lit
E213104 1 X 1.7 kW NO
100 - 120
1 2+G NEMA 5-15P 1.3 – 1.8 12.3 - 14.7 4.4 gal/16.7 lit
E213101 1 X 2.3 kW NO
100 - 120
1 2+G NEMA 5-20P 1.7 – 2.4 16.5 - 19.7 5.8 gal/22 lit
E213105 1 X 2.3 kW NO
200 - 240
1 2+G Cord/No Plug 1.7 – 2.4 8.5 – 10.1 5.8 gal/22 lit
E213107 1 X 3.0 kW NO
200 - 240
1 2+G Cord/No Plug 2.2 – 3.1 10.9 – 13.0 7.7 gal/29.1 lit