9
OUTPUTS
Programming
Items
Factory set
Default
Programming Range
(display)
Notes
Show Summary
• Output Summary
Right Brew FR
Right Bypass FR
Screen Contrast
Screen Brightness
Touch To Return
1540
2150
8
8
FR=Flow Rate ml/min
CBS-2131xts Single Series displays RIGHT SIDE only
Right Valve
Test OR Calibrate
• Right Valve Test (Press to test)
TEST
Press To Test
Runs Valve to verify flow.
Have container under
brewbasket!
’’ ’’ ’’ ’’
• R. Valve Calib
Calibrate
*Flow Rate
1540 ml p m
|_________[]________|
1400 1900
Factory or service use
for flow rate
R. Bypass Valve
Test OR Calibrate
Not on CBS 2130XTS
• Right Bypass
Valve Test
(Press to test)
TEST
Press To Test
Runs valve to verify
flow. Have container
under brewbasket!
’’ ’’ ’’ ’’
• R. Bypass
Valve Calib
Calibrate
*Flow Rate
2150 ml p m
|_________[]________|
1900 2600
Factory or service use
for flow rate
Fill Valve
• Fill Valve Test (Press to test)
TEST
Press To Test
Operates fill valve.
Have container under
both brewbaskets!
Right Basket Lk.
Not on CBS 2130XTS
• Right brew
basket lock test
(Press to test)
TEST
Press To Test
Energizes brew basket
lock. For factory or
service use
Heater
• Heater Test (Press to test)
TEST
Press To Test
Energizes Heater(s)
Use for servicing.
Screen
Brightness OR Contrast
• Screen Contrast Contrast
8
|____________[]____|
1 10
• S. Brightness
Brightness
8
|____________[]____|
1 10
TEST
TEST
TEST
TEST
TEST