EasyManua.ls Logo

Fetco MBS-1221 - F SERVICE MENU

Fetco MBS-1221
26 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Go to fetco.com for the latest versions of all information Page 10 User Guide & Operator instructions MBS-1221 P202Re0August 2021
F SERVICE MENU
Software & Code View and Settings
POSITION
Program Items
Factory set Default
Programming Range
Increments
Notes
F1 Display Firmware
2.1.210323
Displays current
version [4/2021]
F2 Display Bootloader
2.0.210317
Displays current
version [4/2021]
F3 Select Model
MBS-1221
Will need reboot
Scroll to brewer
model Save & Exit
CBS
-1221
CBS
-1231, CBS-1232
CBS
-1241, CBS-1242
CBS
-1251, CBS-1252
CBS
-1261, CBS-1262
M
BS-1221, MBS-1251
TBS
-1221, TBS-1222
NOTE: Overwrites
all user settings
(See below)
F5 Option BB Lock NO NO or YES
Enables brew
basket lock
F8 Backup to USB Follow prompts
Saves
settings
Insert blank USB
F9 Restore From USB
Applies settings
from USB
Insert USB
Will need reboot
F10 Restore Defaults NO NO/YES Reset to factory
F11 Error Log
Lists up to six
codes, in order
1: ; 2: ;3:;4: ;5: ;6:
1=Newest/6=Oldest
LAST six errors only
Newest=first
Oldest=last
See Error Code
Chart for references
F12 Erase Error Log NO +
Toggle +/-
YES or NO
FACTORY USE ONLY.
DO NOT RESET
F13 Service Phone # Service
F15 Override Rt BBS NO NO/YES
Toggle +/-
YES or NO
Disables brew
basket sensor
F17 Override Rt BBL NO NO/YES
Toggle +/-
YES or NO
Disables brew
basket lock

Related product manuals