Data Logging
Log measurements and resulting calculations,
such as Superheat, at chosen spans and intervals.
Save up to 9 Jobs (logs) to the internal ash drive.
MENU/LogData
1. Use ARROWS to scroll through Jobs.
The display will alternate between the % free space on the drive and
the % of space the chosen Job uses.
2. Press ENTER to select.
If a Job already exists in that slot, use ARROWS then ENTER to choose
whether or not you want to save over that Job.
3. Use ARROWS to set the Span (total time).
It’s a good idea to use new batteries if setting up a long span. If
batteries run out during a Job, the log will automatically stop and
save, then the SMAN manifold will turn o.
4. Press ENTER to select.
5. Use ARROWS to set the Interval (time between measurements).
6. Press ENTER to select and begin logging data until the Span ends.
LOG will blink to indicate the log is still active.
Press MENU to exit setup at any time.
Press MENU and select StopLog to stop the Job and return to
standard operation. The Job will be saved.
To save battery life, the screen will turn o after 3 hours of logging,
but will continue to log. Press any button to turn the screen on.
Some buttons and features (including auto power o) are disabled
until the Job ends.
Jobs are saved as .csv les.
Connect to your computer via the micro USB port under the
removable rubber cover. View its internal ash drive just like any
other USB drive.