41
CONTENTS
Options available and their functions
If users would like to use the same fingerprint for daily clocking and to trigger duress
alarm, administrator must enable either one of the following functions.
1
HELp kEy
Select [Yes] to enable. Hold the for 3 second followed by the fingerprint verifi-
cation. Successful verification will trigger alarm system.
2
1:1 TRIG
Select [Yes] to enable. Enter user ID followed by fingerprint verification to trigger
alarm system. During daily clocking mechanism, all users use 1:N fingerprint veri-
fication. All 1:1 fingerprint verification process will trigger alarm system.
3
1:N TRIG
Select [Yes] to enable. Place finger on scanner for fingerprint verification to trig-
ger alarm system. During daily clocking mechanism, all users use 1:1 fingerprint
verification. All 1:N fingerprint verification process will trigger alarm system.
4
pWD TRIG
Select [Yes] to enable. Enter user ID and password for verification to trigger alarm
system. During daily clocking mechanism, all users use fingerprint verification.
Any password verification process will trigger alarm system.
5
aLaRm DELay
To delay the reader to trigger alarm system after verification.
If user would like to enroll another finger to trigger duress alarm, please disable all of
the above option.
Please see the next page to learn to enroll/define a finger to trigger duress alarm.
TO DEFINE DURESS
FINGERpRINT
If users would like to use different fingers for
daily clocking mechanism and to trigger duress
alarm, users must enroll with more than 1 fin-
gerprint (2 or above).
Example, index finger for daily clocking activi-
ties and thumb as duress finger.
When duress finger is used for verification, it
will trigger alarm system as well. Administrator
does not need to enable any of the verification
methods in Duress Alarm Parameters.
Follow the steps shown to define duress finger.

Other manuals for FingerTec TA100C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the FingerTec TA100C and is the answer not in the manual?

FingerTec TA100C Specifications

General IconGeneral
BrandFingerTec
ModelTA100C
CategoryIP Access Controllers
LanguageEnglish

Related product manuals