Fire-Lite MS-9600UDLS User Manual

Fire-Lite MS-9600UDLS
184 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
B8
P/N 52646:B8 ECN 15-642
Document 52646
11/20/2015 Rev:
Addressable Fire Alarm Control Panel
MS-9600LS/MS-9600LSE
MS-9600UDLS/MS-9600UDLSE
MS-9600LSC
Manual

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Fire-Lite MS-9600UDLS and is the answer not in the manual?

Fire-Lite MS-9600UDLS Specifications

General IconGeneral
TypeAddressable Fire Alarm Control Panel
Dimensions14.5" H x 14" W x 3.5" D
Operating Temperature32°F to 120°F (0°C to 49°C)
CompatibilityCompatible with Fire-Lite addressable devices
Operating Voltage24VDC
Power Supply120 VAC, 60 Hz
Output Current3A
Power120/240 VAC, 50/60 Hz
Battery Backup24 VDC
Humidity10% to 93% (non-condensing)
NAC Circuits4 Class A or Class B
Alarm Current3A
Battery Charging Current1A
Relative Humidity10% to 93% (non-condensing)
Number of Zones198

Summary

Fire Alarm & Emergency Communication System Limitations

Installation Precautions

Section 1: Product Description

1.3 Specifications

Details technical specifications for power, communication loops, and relays.

Section 2: Installation

2.1 Mounting

Details the procedures and considerations for physically mounting the FACP cabinet.

2.6 Optional Modules and Devices

Covers installation of various optional modules and devices.

Section 3: Programming

3.2 User Programming

Covers user programming methods, modes, and exiting procedures.

3.5 Programming and Passwords

Details accessing programming modes and managing system passwords.

3.6 Master Programming Level

Details accessing and navigating the Master Programming Level.

3.6.2 Point Program

Allows adding, deleting, or editing addressable device programming.

3.6.3 Zone Setup

Covers enabling, disabling, and configuring zone properties.

3.6.5 System Setup

Allows configuration of panel features like Time-Date, NACs, and Relays.

Section 4: Operating Instructions

4.4 Trouble Operation

Explains how the FACP indicates and responds to system trouble conditions.

4.5 Alarm Operation

Describes how the FACP indicates and responds to alarm conditions.

4.6 Supervisory Operation

Details the FACP's indication and response to supervisory events.

Section 5: Power Supply Calculations

5.3 Calculating the System Current Draw

Provides methods to calculate system current draw for different conditions.

5.4 Calculating the Battery Size

Explains how to calculate the required battery size in ampere-hours.

Appendix C: NFPA Standard-Specific Requirements

Appendix E: Wire Requirements