CAUTION: WHEN INSTALLING AND OPERATING THIS APPLIANCE, ALL INSTRUCTIONS AND WARNINGS IN
YOUR OWNER’S MANUAL MUST BE OBSERVED.
FAILURE TO DO SO MAY RESULT IN A FIRE
OR EXPLOSION CAUSING PROPERTY DAMAGE, BODILY INJURY, OR DEATH.
This grill must be installed in accordance with local codes and ordinances, or, in the absence of local codes, with either the latest National Fuel Gas Code (ANSI
Z223.1/NFPA 54), and Natural Gas and Propane Storage and Handling Installation Code (CSA-B149.1).
This appliance and its individual shutoff valves must be disconnected from the gas-supply piping system when testing the system at pressures in excess of ½ psig.
This appliance must be isolated from the gas-supply piping system by closing its dedicated manual shutoff valve during any pressure testing of the gas-supply
system at pressures up to and including ½ psig.
This grill is designed for outdoor use only. DO NOT use this grill inside a building, garage, or enclosed area (see paragraph below). DO NOT use this grill
in or on a recreational vehicle or boat.
A minimum 5 foot clearance is required between the cooking surface and the overhead construction. When installed under combustible overhead construction,
the area above the cooking surface of the grill must be covered with an exhaust hood. The exhaust hood provides the protection for the combustible overhead
construction. DO NOT use this appliance under unprotected combustible overhead construction.When installed under overhead non-combustible construction,
an exhaust hood is highly recommended. When using an exhaust hood: the area above the cooking surface of the grill must be covered with a hood larger than
the cooking area of the grill, and with a minimum of 1200 CFM (cubic feet per minute) for proper outdoor application.
2-Unpacking
Carefully unpack the grill, removing all packing material and protective film (including the clear
film on the drip tray). Verify that all parts have arrived undamaged by consulting the parts list
in the owner’s manual. Remove foam packed hardware from oven area. (See Fig. 2-1.)
Consult the parts list in the owner’s manual. If any parts are missing or damaged, immediately
contact the Fire Magic dealer before beginning installation.
Important: The 2 shipping screws must be removed prior to removing the unit from the
wooden pallet. The screw located on the bottom left side of the unit is accessed
by opening the door. The screw located on the bottom right side of the unit is
accessed by removing the lower drawer.
To remove the drawer; pull it completely out. Release the drawer from the drawer
slides by pressing the black lever down on the right side, and up on the left side.
Fig. 2-1
1-Safety
Lift out foam packed hardware
Remove plastic
zip-ties
3-Installation
Location
Locate the grill on a flat level surface. Refer to the INSTALLATION
REQUIREMENTS section of your grill owner’s manual for complete details.
CAUTION: Wind blowing into or across the rear oven lid vent (Fig.
3-1) can cause poor performance and/or dangerous
overheating. Orient the grill so that the prevailing wind
blows toward the front of the grill (Fig. 3-2).
CAUTION: To prevent dangerous overheating, the rear of the unit must have
a minimum clearance of 4” from any non-combustible wall.
To connect the regulator/
hose assembly to the
propane-gas cylinder
valve fitting: Press the
hand nut on the regulator
over the Acme thread fitting
on the cylinder valve. Turn
the hand nut clockwise to
engage the threads and
tighten until snug.
U
L
Fig. 3-4 Type I Acme thread quick coupler
Vent
QCC
Type 1
valve
Brass Acme
thread fitting
Liquid level
indicator
(optional)
Hand nut with
Acme thread
Regulator
Hose
Hand wheel
Pressure
relief
valve
Connect Gas supply
These quick start instructions assume a
propane cylinder configured unit.
See
main instructions for natural gas
or household propane configured
units.
Place approved propane 20 lb cylinder in
tank tray and lock holder in position (Fig. 3-3).
Connect quick coupler hose and regulator
supplied with unit to propane cylinder (Fig.
3-4).
Turn all burner control knobs to the OFF
position. Open the main cylinder valve. Then
carefully check all gas connections for leaks
with a brush and half-soap/half-water solution
before lighting. NEVER USE A MATCH OR
OPEN FLAME TO TEST FOR LEAKS.
Proper grill airflow must be maintained as
shown in Fig. 3-5.
IMPORTANT: You must read the installation and owner’s manual provided with the grill.
INSTALLER: Leave these instructions with consumer. CONSUMER: Retain for future reference.
Installation must be performed by a qualified professional service technician.
REV 6 - 1804201255
L-C2-336
ECHELON
diamond series
Stand Alone Outdoor
Gas Grill Quick Start Guide
Fig. 3-2
CORRECT
PLACE GRILL SO PREVAILING WIND
BLOWS TOWARD FRONT OF GRILL
Ventilation diagram
Fig. 3-5
MENU
SET
Fig. 3-3
Quick
coupler
Propane
cylinder (tank)
Sideburner
shelf (if
equipped)
Tool holder
Paper
towel
holder
Backburner
cover
Tank tray latch
Digital thermometer
(if equipped)
Meat probe
(if equipped)
YOU MUST PROTECT REAR OVEN
VENT FROM PREVAILING WIND
Rear oven lid vent
INCORRECT
Fig. 3-1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the FireMagic Echelon diamond series and is the answer not in the manual?

FireMagic Echelon diamond series Specifications

General IconGeneral
BrandFireMagic
ModelEchelon diamond series
CategoryGrill