EasyManua.ls Logo

FireMagic Aurora - User Manual

FireMagic Aurora
40 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
1
IMPORTANT:
READ THESE INSTRUCTIONS CAREFULLY BEFORE STARTING INSTALLATION OR USE.
DANGER:
IF YOU SMELL GAS:
1. Shut off the gas to the appliance.
2. Extinguish any open fl ame.
3. Open lid.
4. If odor continues, keep away from the
appliance and immediately call your
gas supplier or the fi re department.
WARNING:
1. Do not store or use gasoline or other
ammable vapors and liquids in the
vicinity of this or any other appliance.
2. An LP cylinder not connected for use
shall not be stored in the vicinity of this
or any other appliance.
CODE AND SUPPLY REQUIREMENTS: This grill
must be installed in accordance with local codes
and ordinances, or, in the absence of local codes,
with either the latest National Fuel Gas Code
(ANSI Z223.1/NFPA 54), and Natural Gas and
Propane Storage and Handling Installation Code
(CSA-B149.1).
This appliance and its dedicated manual shutoff
valve must be disconnected from the gas-supply
piping system when testing the system at pressures
in excess of ½ psig (3.5 kPa).
This appliance must be isolated from the gas-supply
piping system by closing its dedicated manual
shutoff valve during any pressure testing of the gas-
supply system at pressures up to and including ½
psig (3.5 kPa).
All electrical outlets in the vicinity of the grill must be
properly grounded in accordance with local codes,
or, in the absence of local codes, with the National
Electrical Code, ANSI/NFPA 70, or the Canadian
Electrical Code, CSA C22.1, whichever is applicable.
Keep all electrical-supply cords and fuel-supply
hoses away from any heated surface.
Robert H. Peterson Co. • 14724 East Proctor Avenue • City of Industry, CA 91746
INSTALLER: Leave these instructions with consumer.
CONSUMER: Retain for future reference.
WARNING:
Improper installation, adjustment,
alteration, service, or maintenance can
cause injury or property damage. For
proper installation, refer to the installation
instructions. For assistance or additional
information, consult a qualifi ed professional
service technician, service agency, or the
gas supplier.
SAFETY AND WARNING CODES
STAND-ALONE POST OUTDOOR
GAS GRILLS
INSTALLATION
INSTRUCTIONS AND
OWNER’S MANUAL
Proper operation of your grill requires
prompt and periodic maintenance.
See the CARE & CLEANING section
for details.
Certifi ed to: ANSI Z21.58-2015
CSA 1.6-2015
11-093
US
®
C
REV 1 - 1603020805
L-C2-436
A430s (IN-GROUND AND PATIO MOUNT)
A430s Patio
mount w/ analog
thermometer
shown

Other manuals for FireMagic Aurora

Question and Answer IconNeed help?

Do you have a question about the FireMagic Aurora and is the answer not in the manual?

FireMagic Aurora Specifications

General IconGeneral
Grill TypeBuilt-In
Ignition SystemElectronic
MaterialStainless Steel
Cooking Grid MaterialStainless Steel
Fuel TypeNatural Gas or Propane
WarrantyLifetime on Stainless Steel Components

Summary

Safety and Warning Codes

Gas Leak Safety Procedures

Critical steps to take immediately if you smell gas.

Flammable Material Storage Warning

Warnings against storing flammable liquids and vapors near the appliance.

Code and Supply Requirements

Grill installation must comply with local and national gas codes.

Electrical Outlet Safety

Requirements for grounding electrical outlets in the grill's vicinity.

Getting Started

Electrical Safety Precautions

Guidelines to prevent electric shock during operation and cleaning.

Model Specifications (cont.)

Grill Wiring Diagram

Schematic illustrating electrical connections for the grill components.

Grill Maintenance and Safety

Electrical Connection Guidelines

Specific instructions for connecting the grill to a power source.

Installation Requirements

Overhead Construction Clearances

Minimum safe distances required from overhead structures.

Side and Rear Wall Clearances

Minimum clearances needed from side and rear walls.

Installation Requirements (cont.)

Combustion Airflow and Ventilation

Ensuring proper airflow for optimal grill performance and safety.

Gas Supply Plumbing

Requirements for connecting the gas supply line and valves.

Propane Safety Information

Propane Gas Handling Guidelines

Critical safety rules for using propane gas with the grill.

Propane Tank Installation Safety

Safety measures for installing and positioning propane tanks.

Propane Gas Cylinder Use

Cylinder and Connector Requirements

Specifications for propane cylinders, valves, and hoses.

Patio Mount Installation

Patio Mount Installation (cont.)

Connecting Gas Supply and Leak Testing

Procedures for connecting gas and performing leak tests.

In-Ground Post Installation

In-Ground Post Installation (cont.)

Connecting Gas Supply and Power

Final gas and power connections for in-ground installation.

Leak Testing and Reconnecting Wires

Performing leak tests and reconnecting electrical components.

Lighting Instructions

Optional Digital Thermometer

Optional Digital Thermometer Settings

Optional Digital Thermometer Settings (cont.)

Optional Infrared Burner Operation

Care and Cleaning Procedures

Gas Type Conversion

Gas Type Conversion (cont.)

Burner Air Shutter Adjustment

Burner Air Shutter Adjustment (cont.)

Troubleshooting Guide

Ignition System Issues

Diagnosing and resolving problems with the ignition system.

Flame and Heat Issues

Troubleshooting low flame, insufficient heat, and uneven heating.