4. Fully open the LPG cylinder knob.
5. Turn the fuel selector switch toLPG” position.
3. Connect the regulator to both LPG cylinder and
generator.
NOTE: When the fuel selector switch is turned
to the “LPG” position, the indicator light will
become RED up to 4 minutes(before goes off).
Starting the engine successfully during these
4 minutes will turn the indicator light GREEN.
6. Disconnect all electrical loads from the
generator. Never start or stop the generator
with electrical devices plugged in or turned
on.
7. Move choke lever located on engine to “START
position.
NOTE:
Do not place the LPG cylinder in the path of muffler outlet.
9.Move the choke lever to theRUN position.
11. Allow generator to run at no load for few
minutes upon each initial start-up to permit
engine and generator to stablize.
8. PULL TO-PRIME:-
Pull the starter cord 1-2 times. Pull slowly until
resistance if felt and then pull rapidly.
10. PULL TO RUN:- -
Pull the starter cord slowly until resistance if felt
and pull rapidly to run the unit.
If the engine fails to start in 1-2 pulls with choke in the
RUN” position, then move choke lever toSTART
position and repeat the “PULL-TO-PRIME” step.
REMINDER: MUST HAVE SOLID RED INDICATOR
LIGHT TO BE ABLE TO START THE GENERATOR.
THE GENERATOR CANNOT BE STARTED DURING
BATTERY POWER SAVING MODE UNLESS
1-2 Times
English Page 19
Support: support@arcaugusta.com

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Firman P03612 and is the answer not in the manual?

Firman P03612 Specifications

General IconGeneral
BrandFirman
ModelP03612
CategoryPortable Generator
LanguageEnglish

Related product manuals