EasyManuals Logo

Firman P03615 User Manual

Firman P03615
42 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #33 background imageLoading...
Page #33 background image
TROUBLE SHOOTING
Page 29
English Customer Service: 1-844-FIRMAN1
Problem Cause Correction
Engine is running, but no
AC output is available.
1. Circuit breaker is open.
2. Overload light is on.
3. Poor connection or defective cord
set.
4. Connected device is bad.
1. Reset circuit breaker.
2. Review the load and restart the unit.
3. Check all connections and cord set.
4. Replace defective device.
Engine runs good at
no-load but bogs down
when loads are connected.
1. Clogged or dirty fuel filter.
2. Clogged fuel line.
3. Generator is overloaded.
4. Clogged spark arrester.
1. Clean or replace fuel filter.
2. Clean the fuel line.
3. Check the load and adjust.
4. Clean or replace spark arrester.
Engine will not start; starts
and runs rough or shuts
down when running.
Engine lacks power.
Enginehuntsor falters.
1. Fill crankcase to proper level/
Place generator on level surface.
2. Fill fuel tank with gasoline .
3.Replace spark plug.
4. Connect wire to spark plug.
5. Clean or replace the fuel filter.
6. Charge or replace battery.
7. Adjust the choke position.
8. clean or replace spark arrester.
1. Low oil level sensor.
2. Out of fuel.
3. Bad Spark plug.
4. Spark plug wire not connected to
spark plug.
5.Clogged or dirty fuel filter.
6. Out of battery power.
7. Choke in the wrong position.
8. Clogged spark arrester.
1. Load is too high
2. Dirty air filter
3. Clogged or dirty fuel filter
4. Clogged spark arrester
5.Overheating
6. Choke in the wrong position
1. Check the load and adjust
2. Clean or replace the air filter
3. Clean or replace fuel filter
4. Clean or replace spark arrester
5. Check for air restriction, Move to
a well ventilated area
6. Adjust the choke position
1. Clogged or dirty fuel filter
2. Fuel tank low (gasoline)
1. Clean or replace fuel filter
2. Add fuel.

Questions and Answers: