Troubleshooting – Specifications
English Customer Service: 1-844-FIRMAN1
Problem Cause Correction
Engine is running, but no
AC output is available.
1. Circuit breaker is open.
2. Fault in generator.
3. set. Poor connection or defective cord
4. Connected device is bad.
1. Reset circuit breaker.
2. Contact authorized service facility.
3. Check and repair.
4. Connect another device that is in
good condition.
Engine runs good at
no-load but bogs down
when loads are connected.
1. Short circuit in a connected load.
2. Engine speed is too slow.
3. Shorted generator circuit.
1. Disconnect shorted electrical load.
2. Contact authorized service facility.
3. Contact authorized service facility.
Engine will not start; starts
and runs rough or shuts
down when running.
1. Fuel selector switch set to OFF (O)
position.
3. Low oil level.
4. Dirty air cleaner.
5. Out of gasoline.
6. Stale gasoline.
7. Spark plug wire not connected to
spark plug.
8. Bad spark plug.
9. Water in gasoline.
10. Flooded.
11. Excessively rich fuel mixture.
1. Set fuel selector switch to “GAS”
or “LPG/NG” position.
3. Fill crankcase to proper level or
place generator on level surface.
4. Clean or replace air cleaner.
5. Fill fuel tank with gasoline.
6. Drain fuel tank and carburetor; fill
with fresh gasoline.
7. Connect wire to spark plug.
8. Replace spark plug.
9. Drain gas tank and carburetor; fill
with fresh gasoline.
10. Wait 5 minutes and re-crank engine.
11. Contact authorized service facility.
Engine lacks power.
1. Load is too high.
2. Dirty air filter.
1. Don't Overload Generator
2. Replace air filter.
Enginehuntsor falters.
1. Carburetor is running too rich or too lean.
1. Contact authorized service facility.
12. Clogged or dirty fuel filter.
4. Clean or replace fuel filter.
12. Clean or replace fuel filter.
3. Clogged or dirty fuel filter.
4. Clogged spark arrester.
3. Clean or replace fuel filter.
4. Clean or replace spark arrester.
2. Clogged or dirty fuel filter.
2. Clean or replace fuel filter.
Engine shuts down when
running.
1. Out of gasoline.
2. Dirty air cleaner.
3. Low oil level.
1. Fill fuel tank with gasoline.
2. Clean or replace air cleaner.
3. Fill crankcase to proper level or place.
generator on level surface.
4. Clogged or dirty fuel filter.
13. Starting battery may have
insufficient charge.
13. Check battery output and charge
battery as necessary.
2. The indicator light is OFF or
flashing red.
2. Must have solid red indicator light
to be able to start the engine.
14. Out of battery power.
14. Manually start engine.
For all other issues, contact authorized dealer or Firman customer service.