https://
install.myfirstech.com
Copyright 2020 Fi rste ch, LLC. “Hello, my name is Inigo Montoya....” Page
42
2-04 Trigger Start: This feature changes the number of pulsed inputs (min of 60mS per pulse) required to
activate the remote start sequence using the trigger start input wire. (Pink wire, pin 14, CN5). Note: If
option 4 is selected and OEM remote control feature is available through data, the Control Module
will accept 3 OEM lock commands to activate the start sequence.
FO1 - Off: (default)
FO2 - Single pulse: This option will trigger the remote start sequence with a single pulsed input to the
trigger start wire. This is ideal when adding accessories that can trigger the CMX.
FO3 - Double pulse: This option will trigger the remote start sequence with 2 pulses to the trigger start
input wire. This can be used when integrating with an OEM keyless entry remote.
FO4 - Triple pulse: (MUST BE USED WHEN 3X’s LOCK IS DESIRED) This option will trigger the
start sequence with 3 pulses to the trigger start input wire. This is ideal when trying to integrate the OEM
keyless entry remote. Note: this option will also allow the CMX to accept a 3-pulse input from OEM
remote commands through data.
2-05 Cold or Hot Start: Note: the Firstech thermistor temp sensor must be connected to the CMX in order
to use these options. This feature turns on the cold/hot Timer start features.
FO1 - Off: (default)
FO2 - Cold start: This option enables the thermistor when using Timer Start Mode. It will start the car
at the preset cold temperature (see feature 2-08) according to the selected timer start option (see feature
2-06)
FO3 - Hot Start: This option enables the thermistor when using Timer Start Mode. It will start the car
at the preset hot temperature (see feature 2-09) according to the selected timer start option. (see feature
2-06)
FO4 - Cold and Hot start: This option enables the thermistor when using Timer Start Mode. It will
start the car at the preset Cold and Hot temperature (see features 2-08 and 2-09) according to the
selected timer start option (see feature 2-06)
2-06 Timer Start: This feature is designed to allow the user to have the CMX automatically remote start
at the end of a selected timed cycle. It also be controlled by the thermistor, or a selected time by 2 way
remote, so it will start at a specified temperature at the end of the timed cycle or a specific time.
FO1 - 3-hour cycle: (4-minute runtime, 8-minute runtime for diesel) Once Timer Mode is enabled (see
feature 2-13) the CMX will wait 3 hours, remote start and run for 4 minutes unless the cold start feature
is enabled. If this is the case, the CMX will check the temperature once every 3 hours. If it is at or below
the selected temperature, (see feature 2-08) it will start and run for 4 minutes. The same procedure will
apply to the hot start feature. If there is any interaction with the CMX after timer mode has been
activated using the Firstech remote or accessory, timer mode will be cancelled and must be re-started to
start a new timed cycle.
FO2 - 2 hour repeat with cold starting: (runtime based on feature 2-07 option setting and cold start
setting based on feature 2-08) Note: 2-way LCD remote required. This option is designed to monitor
the temperature 2 hrs. After timer mode is set and start if it is at or below the preset cold
start temperature (see feature 2-08). This process will continue until the user manually starts or remote
starts the vehicle.