EasyManua.ls Logo

Firstech CM-X - Page 43

Firstech CM-X
76 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CMX is t
he
Solution
https://
install.myfirstech.com
CMX
Master
Guide
Copyright 2020 Fi rste ch, LLC. “Hello, my name is Inigo Montoya....” Page
43
FO3 - Reserved Timer: (runtime based on feature 2-07 option setting) Note: 2-way LCD remote
required. This option will allow the user to set a predetermined time to remote start on the 2 ways
LCD remote. Once the timer mode is activated it will start the countdown timer on the CMX based on
the difference of time between what the remote clock is set to and the timer mode time is set to. (NOTE:
Must be a minimum of 20 minutes from current time displayed on the remote.)
I.e. remote time reads 7:00pm and timer mode time is set to 7:00 am the CMX will activate the timer
mode to go for 12hours before it starts. Note: it is important that the remote time is as accurate as
possible when activating the timer mode to ensure that it will start at the desired time. If there is any
interaction with the vehicle or system after timer mode has been activated, it will cancel the timer.
FO4 - 24 hour repeat with cold starting: (runtime based on feature 2-07 option setting and cold start
setting based on feature 2-08) Note: 2-way LCD remote required. This option is designed to monitor the
temperature 24 hrs. After timer mode is set and start if it is at or below the preset cold
start temperature (see feature 2-08). This process will continue until the user manually starts or remote
starts the vehicle.
2-07 Remote Start Runtime: This feature consists of four different settings for the remote start run time.
FO1 - 15 minutes (default)
FO2 - 25 minutes
FO3 - 45 minutes
FO4 – 3-minute (default) PROGRAMABLE: 1-45 Minutes at 1-minute increments (using the OP500
programmer with software v.30 or newer that can be found at www.install.myfirstech.com)
2-08 Cold start Temperature: This feature allows the user 4 different temperature settings for cold start
operation
FO1 - 14°F/-10°C: will activate the start sequence at the end of the time cycle (set by feature 2-06
option setting) if temperature is at or below this temperature.
FO2 - -4°F/-20°C: will activate the start sequence at the end of the time cycle (set by feature 2-06
option setting) if temperature is at or below this temperature.
FO3 - 23° F/-5° C: will activate the start sequence at the end of the time cycle (set by feature 2-06
option setting) if temperature is at or below this temperature.
FO4 - 5° F/-15° C (default) PROGRAMMABLE -30 ~ 0 [°C] / -22 ~ 32 [°F]: (using the OP500
programmer with software v.30 or newer that can be found at www.install.myfirstech.com) will activate
the start sequence at the end of the time cycle (set by feature 2-06 option setting) if temperature is at or below
this temperature.
2-09 Hot Start Temperature: This feature allows the user 4 different settings for hot start operation
FO1 - 77° F/25° C: will activate the start sequence at the end of the time cycle (set by feature 2-06
option setting) if temperature is at or above this temperature.
FO2 - 86° F/30° C: will activate the start sequence at the end of the time cycle (set by feature 2-06
option setting) if temperature is at or above this temperature.
FO3 - 95° F/35° C: will activate the start sequence at the end of the time cycle (set by feature 2-06
option setting) if temperature is at or above this temperature.