https://
install.myfirstech.com
Copyright 2020 Fi rste ch, LLC. “Hello, my name is Inigo Montoya....” Page
54
FO4 - Input trigger: this option will activate the AUX 1 output (output timing based on feature
4-01) When a PIC (programmable input channel) set to AUX1 Trigger Input sees a pulsed or latched
ground source.
4-04 Aux 2 Output Control: This feature allows the user to configure the method of which Auxiliary 2 can be
activated.
FO1 - Remote: (default) this option allows AUX 2 (output time based on feature 4-02) to be
triggered by any 4 button Firstech remote or drone.
FO2 - With Arm: this option will trigger AUX 2 (output time based on feature 4-02) any time the
CMX is locked/armed the first time (I.e. if you send a second lock/arm command it will not trigger
again)
FO3 - With Start: this option will trigger AUX 2 (output time based on feature 4-02) any time the CMX
remote start sequence is activated. Note: this output timing will trigger at the same time as GWR (status
output)
FO4 - Input trigger: this option will activate the AUX 2 output (output timing based on feature
4-02) When a PIC (programmable input channel) set to AUX2 Trigger Input sees a pulsed or latched
ground source.
4-05 Secure Aux Output: this feature is designed to prevent accidental activation of the AUX outputs by
requiring an additional step when using any 4 buttons or 2-way LCD Firstech remote.
FO1- On: (default) this option will require the user to perform an additional step before activating AUX
output using any Firstech 4 button or 2-way LCD remote (2way remotes with Roman numeral buttons
will require a 0.5 second tap of button IV before activating any of the AUX outputs.2Way LCD remotes
with lock/unlock/trunk/start icons on the buttons use the start button for the same. 1way remotes require
the user to hold trunk + start buttons for 2.5 seconds before activating AUX outputs.) FO2- Off: this
option will disable the additional step required by the user to activate the AUX outputs.
FO3- On while armed: this feature will only require the user to perform the additional override step
to activate Aux outputs ONLY WHEN the CMX is ARMED. While the system is disarmed or
unlocked this step is not required.
4-06 Hazard Light output timing: Applicable to Hazard Light POC SV30 This feature offers optional time
interval between on and off pulses, to accommodate different hazard light timing.
FO1- 400mS(default): When using POC SV 30 the CMX will provide a negative output (on) to activate
the hazard light circuit. 400mS after the first output the CM will produce another output (off) to
deactivate the Hazard Light circuit. This should result in a single parking light flash, but if there are no
flashes or too many flashes you will have to try the other options.
FO2- 600mS: When using POC SV 30 the CMX will provide a negative output (on) to activate the
hazard light circuit. 600mS after the first output the CM will produce another output (off) to deactivate
the Hazard Light circuit. This should result in a single parking light flash, but if there are no flashes or too
many flashes you will have to try the other options.
FO3- 800mS: When using POC SV 30 the CMX will provide a negative output (on) to activate the
hazard light circuit. 800mS after the first output the CM will produce another output (off) to deactivate
the Hazard Light circuit. This should result in a single parking light flash, but if there are no flashes or too
many flashes you will have to try the other options.