2-14 PIC 1 (-): Programmable Input Channel provides 4 options for negative input to the CM7.
FO1 - (-) negative E-brake (aka: parking brake) input: This option allows the CM7 to read
input as e-brake which is needed to enter reservation mode or turbo timer mode. (Note: required for
manual transmission or turbo timer mode).
FO2 - (-) negative parking light reminder input: This option allow the CM7 to read input as
parking light reminder. If this input has ground, as soon as the system is locked/armed it will send a
notification to a 2 way LCD or Drone indicating parking lights are still on.
FO3 - (-) Trigger start input: This option will enable PIC1 to be used as a trigger for activating
the remote start function using a number of (-) pulses based off of feature 2-04 using the lt. Blue wire
CN5.
3-01 Parking Lights while Remote Started: This feature changes the parking light behavior during remote
start.
FO1 - Constant output: This option will keep the parking light output (+ and -) on steady
throughout the entire runtime (runtime based on feature 2-07 selection)
FO2 - Flashing output: This option will flash the parking light output (+ and -) throughout the
entire runtime (runtime based on feature 2-07 selection)
FO3 - Off: This option turns the parking lights off while the vehicle is remote started.
FO4 - Off with lock and unlock only: This feature is designed to eliminate redundant parking
light flash with lock/unlock when interface module flashes the parking lights controlling the Factory
security.
3-02 Confirmation chirps: This feature will allow the user to select a shorter siren output time to simulate a
quieter arm/disarm/start output.
FO1 - 30mS: This is a 30 milliseconds siren output with arm, disarm, and start confirmation chirps.
It will produce a “medium” volume sound. (Softer than the standard 60mS output)
FO2 - 15mS: This is a 15 millisecond siren output with arm, disarm, and start confirmation chirps. It
will produce a “short” or quiet volume of sound. (Significantly softer than the standard 60mS output)
FO3 - 60mS: This is a standard 60 millisecond siren output with arm, disarm, and start confirmation
chirps.
Copyright 2014 Firstech, LLC. Page 3Copyright 2014 Firstech, LLC. Page 3Copyright 2014 Firstech, LLC. Page 37
CM7200 Master Guide
Starter System