EasyManua.ls Logo

Firstech CM7200 - Door Lock;Unlock Pulse Duration; Driver’s Priority Unlock; Double Pulse Unlock; Rearm Output: Factory Alarm Arm (FAA) Output Function Options

Firstech CM7200
55 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Copyright 2014 Firstech, LLC. Page 3Copyright 2014 Firstech, LLC. Page 3Copyright 2014 Firstech, LLC. Page 29
CM7200 Master Guide
Starter System
techfeed.compustar.com
1-02 Door Lock/Unlock Pulse Duration: This does not affect the behavior of the factory arm output (orange
wire) or factory alarm disarm output (orange/white wire).
FO1 - 0.8 seconds: (-) Negative lock and unlock output time.
FO2 - 2.5 seconds: (-) Negative lock and unlock output time.
FO3 - 0.125 seconds: (-) Negative lock and unlock output time. This option may be helpful when
using lock/unlock to arm/disarm vehicles that may roll windows down with factory Arm/Disarm wires
when the standard output is too long.
FO4- 3.5 seconds: (-) Negative lock and unlock output time.
1-03 Driver’s Priority Unlock:
FO1 - Off: (default)
FO2 - On: This feature will allow the user to unlock the driver’s door first. If the unlock button is
pressed again within 4 seconds, the other doors will unlock. The driver’s door unlock must be isolated
from the other doors and use the blue (-) unlock. The Orange/Black (-) 2nd unlock (POC setting) is
used to provide unlock output to unlock all other doors.
1-04 Double Pulse Unlock:
FO1 - Off: (default)
FO2 - Unlock: This option will provide a double pulse output only for unlock each time the CM7
executes the unlock command. (Length of output time will be based on feature 1-02 option settings.)
FO3 - Lock: This option will provide a double pulse lock output only for lock each time the CM7
executes the lock command. (Length of output time will be based on feature 1-02 option settings.)
FO4 - Lock and unlock: This option will provide a double pulse lock output for both lock and
unlock each time the CM7 executes lock or unlock commands. (Length of output time will be based
on feature 1-02 option settings.)
1-05 Rearm Output: Factory Alarm Arm (FAA) output function options
FO1 - After start, after shutdown, after first lock: This option triggers the FAA after every
successful remote start, every successful remote start shut down, and with every first lock command.
(First lock command is the first arm/lock command sent after the CM7 has been disarmed or
unlocked.)
FO2 - After shut down only and first lock: This option triggers the FAA after every successful
remote start shut down, and with every first lock command. (First lock command is the first arm/lock
command sent after the CM7 has been disarmed or unlocked.)
FO3 - After Start only: This option triggers FAA after every successful remote start.
FO4 - After shutdown only: This option triggers the FAA after every successful remote start shut
down.

Table of Contents

Related product manuals