5.4.3 Cross Rail
The cross rail contains part of the condenser copper tubing (mullion heater) providing heat to the gasket area
between the PC and FC compartments, preventing sweating of the gasket. Also mounted on the cross rail is
the Reed Sensor, under the plastic cover in the centre.
5.4.4 Divider Partition
This is moulded in two outer pieces and has an inner polystyrene moulded duct assembly that is wax coated.
This provides a barrier between the FC and PC compartments, also allowing return air from the PC to move
back to the FC evaporator in ‘T’ models. In both models it houses the PC fan motor. The divider is fitted into
the cabinet as an assembly and cannot be replaced.
“B” DIVIDER PARTITION
Diagram 5.4.4