Fig. 8d Gas mains connection area
Converting to a Different Gas Type
This appliance is suitable for use with Natural gas or LPG (check the “gas type” sticker attached to the appliance). To
convert from one gas type to another, you need to replace the injectors, and then adjust the minimum burning setting.
Replacing the Injectors
1. Remove the trivets and burners from the cooktop.
2. Using a spanner, remove the injectors (shown in Figs. 91011 beloow) and replace them with ones according
to the gas type (see the ‘Table for the Choice of Injectors’).
3. Fix the warning label (supplied with the conversion kit) at the back of the cooker, near the gas inlet connection.
This label states that the gas cooktop has been converted for use with LPG/ Natural gas.
4. Adjust the minimum burner setting. See ‘Adjusting the Minimum Burner Setting' section below.
The burners are designed so that regulation of the primary air is not required.