8.0 Prime the Genius
®
FreeFlow
Dispense Tip
8.1 Remove tip cap from the barrel
by twisting counter-clockwise
and pulling. Attach the same
dispense tip being used
on the automation system.
8.2 Hold the dispense tip over the provided
dot chart as shown, press the foot pedal
intermittently until the uid begins to ow
towards the end of the Genius
®
dispense tip.
Goal: To stop the uid when ush with the end of the Genius
®
dispense tip with no air pockets.
8.3 If too little uid: Continue
to press on the foot pedal
intermittently causing the
uid to ow to the tip.