Maintenance
The V3+ display itself is maintenance-free, however it is recommended to perform the following checks, if
problems are suspected and/or general maintenance check-ups are planned:
o Do all LED’s illuminate during the start-up test?
o Does the Mode button function correctly; dirt/dust particles can obstruct its function?
o Is the buzzer opening (display lower edge) free from dirt or adhesive residues?
o Are all 4 levels by volume adjustment (short push, < 0.8 s) audible?
Do not forget the FLARM
TM
mainframe during the same check-up:
o Is the software & fixed-obstacle database up-to-date?
o Are the antennas undamaged and properly installed?
o Are the cables/plugs undamaged and properly installed?
Software Update
The V3+M display is equipped with a boot-loader – this allows updating of integrated display software.
Should FLARM
TM
make changes/additions on current data communication or adjustments to the
operating/indication of different warning levels, the display software can be updated.
Only in exceptional cases is the update of the display consequent to a FLARM
TM
update mandatory. As a
rule FLARM
TM
updates are compatible with current peripheral devices – but can include new functions and
operations.
Further information regarding updates is located on: http://www.flarm.com/support/updates/
Updated display software is found on our web-site: www.swiss-bat.ch;
Included on website are steps for software updates for the display.
Technical data
Dimensions: 25 * 63 * 5.6 mm excl. RJ12-jack
(Jack additional app. 10 mm backwards)
Weight: 11.6 g (display without cable and adapter)
Supply voltage: VCC DC directly from FLARM,
Power consumption: average consumption 12 mA by 12V (144 mW)
Protection class: IP52
Attachment: Panel attachment (adhesion or screw)
Temperature range: -20°C…60°C
Humidity: 10-90%, no condensation
Vibrations: For applications in strong vibrating conditions e.g. helicopter,
Powered aircraft.
Manufacturing
country:
Switzerland
Further technical information, tips and problem solving are located on our homepage www.swiss-bat.ch