IF SPILLAGE IS DETECTED
The cause must be discovered and the fault corrected. If the fault cannot be cor-
rected disconnect the appliance from the gas supply and seek expert advice.
Possible causes of spillage from the appliance are:- chimney restriction, down
draught or insufficient air supply to the room.
g) After ensuring that the fire is safe to use it should be left on “High”
position to fully warm up. During this time a slight odour may be
noticed, this is due to the “newness” of the fire and will soon disappear.
3.4 Final Check
a) Refit the Dress-guard if it has not already been re-fitted.
b) Recheck the operation of the fire on all settings.
c) Make sure that the User knows how to operate the fire and refer them
to the User Book.
d) Inform the User that the Model Number for ordering parts is shown on
the Rating plate. The rating plate can be viewed at the bottom left hand
side of the rear panel.
e) Inform the User the fire should be serviced annually for continued safe
operation.
f) Hand this instruction booklet to the customer.