APPLIANCE DATA
Main injector (1 off) Bray Elbow size 420, Cat 82
Pilot Type. Copreci Single Flame
Type 21100 / 141
Max. Gross Heat Input : 6.6 kW
Min. Gross Heat Input : 2.0 kW
Cold Pressure : 20.0 +/- 1.0 mbar (8.0 +/- 0.4 in w.g.)
Ignition : Rotary piezo, integral to gas valve
Electrode Spark Gap : 4.0 mm
Weight (Packed) : 19kg
Firebox Dimensions (with case fitted)
Width : 710mm
Height : (without feet fitted) 680mm
Depth : 255mm
Height to top of the flue spigot : 525mm (with feet fitted)
Gas Connection : 8mm compression
(Supplied with fire)
3