EasyManua.ls Logo

FLENDER H Series - Page 92

FLENDER H Series
110 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Possible faults Causes Possible remedies
Main drive motor does
not start
Motor direction of rotation incorrect
● Change polarity of motor
Backstop cage with sprags incor‐
rectly installed or defective
● Contact Customer Services
● Install the backstop cage, rotated through 180° - or replace
Overrunning clutch blocked
● Contact Customer Services
● Replace the overrunning clutch
Overrunning clutch cage with
sprags incorrectly installed and/or
defective
● Contact Customer Services
● Install the overrunning clutch cage, rotated through 180°
- or replace
Main drive motor can
start while the auxiliary
drive is operational
Defective electrical interlocking be‐
tween the main and auxiliary motor
● Check the connections
● If necessary, replace defective devices
Defective speed monitoring
● Check the connections
● If necessary, replace defective devices
Auxiliary drive motor
does not start
Overload at the output
● Reduce the load at the output
Defective auxiliary drive motor
● Repair the motor or replace
Motor brake not released
● Correct the electrical connection of the motor brake
● If required, replace the motor brake
The auxiliary drive mo‐
tor starts, the main
gear unit output shaft
does not turn
Motor direction of rotation incorrect
● Change polarity of motor
Overrunning clutch cage with
sprags incorrectly installed
● Contact Customer Services
● Install the overrunning clutch cage, rotated through 180°
- or replace
Defective overrunning clutch
● Contact Customer Services
● Replace the overrunning clutch
Leaks
Inadequate sealing of the housing
cover or joints
● Seal housing cover or joints
Labyrinth seals oiled up or transport
position incorrect
● Check oil filling
● Clean the labyrinths
Inadequate sealing of the housing
cover or joints
● Check the seals
● Replace, if necessary
● Seal housing cover or joints
Defective rotary shaft sealing rings
● Check the rotary shaft sealing rings
● Replace, if necessary
Servicing
8.4 Possible faults
Gear unit 5118en
92 Operating Instructions 10/2017