CMA recommend change of hydraulic oil every 5000 work hours.
Any ISO Viscosity Grade 46 Hydraulic Oil will work for this model.
Guarantee
The machines have a one year warranty against manufacturer defect from the date of
delivery. Cases of incorrect use or incorrect connection are not covered by the warranty.
(Due to constant product improvement, the manufacturer reserves the right to modify
machines without prior notice.).
Improper Shutdown:
• Turning the machine off with the lockout breaker before turning off the machine with the red
button.
• Turning the lockout breaker to off before the motor in the power pack has spooled down
completely. (approximately 3 seconds)
• Suddenly removing power from the machine i.e. pulling the plug out of the wall before turning
off the machine with the red button.
• Unplugging the unit before the motor in the power pack has spooled down completely.
(approximately 3 seconds)
• Pressing the green button while lockout breaker is off and residual power is still in the inverter
(approximately 45 seconds after shutdown)
If improper shutdown occurs:
Reset the power pack:
1. Lockout breaker off
2. Unplug the machine (wait 45 seconds to allow the inverter to reboot)
3. Plug the machine back in
4. Lockout breaker on
5. Green button press on (Hold for 2-3 seconds on initial startup)