Correct handling and maintenance is absolutely necessary.
Read the following instructions for installation and operation carefully.
GH-18 Operations Manual
Machine Power: 2Hp
Voltage: 110V
1-800-837-2503
705 Commerce Drive
Wapakoneta, Ohio 45895
www.flexmachinetools.com
info@flexmachinetools.com
FlexArm Inc
GH-18 Tapping Arm Manual
10/17/2019
REV. 001
1
Question and Answer IconNeed help?

Do you have a question about the FlexArm GH-18 and is the answer not in the manual?

FlexArm GH-18 Specifications

General IconGeneral
BrandFlexArm
ModelGH-18
CategoryIndustrial Equipment
LanguageEnglish

Summary

Installation

Arm Mounting and Counterbalance

Mount arm in pivot, adjust counterbalance to prevent operator striking.

Electrical Supply and Motor Rotation

Connect to 110V supply, check hydraulic motor clockwise rotation.

Operational Safety

Wear safety glasses, secure workpiece, avoid gloves during operation.

Machine Specifications

Designed for tapping up to M18, manufacturer not liable for misuse.

GH-18 Startup and Shutdown Procedures

Startup Sequence

Plug in, engage lockout breaker, press green button for 2-3 seconds.

Shutdown Sequence

Press red button, disengage lockout breaker after motor spool down.

Improper Shutdown Handling

Identifying Improper Shutdown

Common causes: incorrect button order, premature power removal, unplugging before motor spool down.

Power Pack Reset Procedure

Steps to reset: breaker off, unplug, wait, plug in, breaker on, press green button.

Product Guarantee and Warranty

Warranty Coverage

One year warranty against manufacturer defects; excludes misuse or incorrect connections.

Tap Lubricator System Operation

Lubricator System Overview

FlexArm units feature a standard tap lubricator system.

Setup and Filling

Connect air, fill oil tank to maximum level.

Operation and Adjustment

Use starting lever, adjust oil mixture with regulator.

Important Caution

Avoid corrosive oils to prevent damage to plastic valves.

Multi-Position Head Operation

Head Positioning

Adjust tapping head position using large and small levers.

Tapping Preparation

Verify small lever is loose for proper tapping.

Securing Head for Tapping

Ensure both levers are secure when returning head to vertical for tapping.

Machine Component Diagram

Technical Specifications

Electric Diagram

Electrical Parts List

Hydraulic Diagram

Hydraulic Parts List

Spare Parts Diagram