For this option, Web Services must be enabled. The gateway will pick up its identier just before
the initial connection to the FTP server. The ID will be lled in with the value returned by the
Web Services server. Should the variable “ID” be deleted once more (“ID= “), the gateway will
request a new identier on its next connection.
3. Connection mode:
Choose “Ethernet” or “Modem”, depending on the mode to be used for the connection.
Ethernet: if the connection mode chosen is “Ethernet”, enter parameters that are valid for your Ethernet
network:
• Address mode: you can obtain the Ethernet parameters automatically if the network
infrastructure and the version of the WebdynPulse can handle this. If this is the case, click the
dynamic radio button and consult the conguration of your DHCP server to nd the IP address
attributed to your gateway.
• IP Address: enter the IP address at which the WebdynPulse gateway is accessible.
• Mask: enter the subnet mask for your network. This mask limits the Ethernet network to one
range of dened IP addresses, and separates one network range from another.
• Gateway: enter the address of the gateway to your network. The gateway address is the IP
address IP of the device that establishes the connection to the Internet. In general, the address
entered here is that of the router or ADSL modem.
• DNS: enter the address of the DNS server. The DNS (Domain Name System) server translates
symbolic Internet addresses (e.g. “www.webdyn.com”) into their corresponding IP addresses.
Here you should enter the address of the DNS server you received you’re your Internet Service
Provider (ISP). You can also enter the IP address of your router or ADSL modem.
If a network administrator manages your Ethernet network, contact him or her to have your
WebdynModbus gateway included in the existing Ethernet network.
Modem: if the connection mode chosen is “Modem”, enter parameters that are valid for your GPRS
subscription:
• Call number: enter the phone number for the GPRS connection. The default number is
“*99***1#”, which is valid in most cases. This number is not the phone number of the SIM
card tted to the unit.
• APN: enter the Access Point Name (APN) supplied by your mobile operator.
• Login: enter the user ID for the APN supplied by your mobile operator.
• Password: enter the password for the APN supplied by your mobile operator.
Consult your mobile operator to obtain the information pertaining to your SIM card (APN, user ID
and password).