EasyManua.ls Logo

Flint & Walling PB2717S303A - User Manual

Default Icon
15 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
1
© 2020 FLINT & WALLING, INC. • 95 North Oak St. • Kendallville, IN 46755
flintandwalling.com
Description
Pressure booster pumps increase water pressure from city mains or private water systems.
Applications include providing high water pressure for washing buildings, dairy walls or
floors, hog parlors, poultry houses, rinsing or spray cooling equipment, lawn sprinkling and
insecticide spraying.
Single-phase models are equipped with a capacitor start, thermal protected motor. Three-
phase models require separate overload protection.
Unpacking
When unpacking the unit, inspect
carefully for any damage that may have
occurred during transit.
NOTE: Use pump with clear water only.
132934 F
Pressure Booster Pumps
Operating Instructions & Parts Manual
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect
yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain
instructions for future reference.
IL0391B
3.88
3.25 "C"
"F"
3.75
9.75
1-1/2 & 2HP 1Ø TEFC
ALL 3HP 1Ø
6.50
7.15
4.88
TEFC ONLY
5.28
2 & 3HP
1Ø TEFC ONLY
1.44
"H" INLET
"J" DISCHARGE
Figure 1
Pump Dimensions 60 Hz Chart A
HP GPM Stage “C”
F
H J
F&W
TEFC
1 Phase 3 Phase
1/3 5 8 10.19 19.81 - - .75 .75
1/3* 5 8 10.19 20.06 22.04 - .75 .75
1/2 5 12 13.38 23.25 23.23 24.10 .75 .75
1/2* 5 14 14.97 25.34 26.82 25.69 .75 .75
3/4 5 16 16.54 26.91 28.77 27.51 .75 .75
3/4 7 12 13.38 23.75 25.61 24.35 .75 .75
3/4* 7 14 14.97 25.84 27.20 25.94 .75 .75
1 10 14 16.31 27.18 29.16 28.02 .75 .75
1-1/2 10 16 18.13 29.62 31.48 30.07 .75 .75
1* 10 20 21.69 33.18 34.54 33.40 .75 .75
1* 10 22 23.50 34.99 36.35 35.21 .75 .75
1* 10 23 24.38 35.87 37.73 36.09 .75 .75
2 19 14 17.89 29.88 32.12 30.87 .75 .75
1-1/2* 19 20 24.06 36.05 37.41 36.00 .75 .75
2* 19 22 26.13 38.12 40.36 39.11 .75 .75
2 27 11 15.38 27.37 29.61 28.36 1.00 1.00
3 27 14 18.50 30.49 33.85 33.35 1.00 1.00
2* 27 17 21.59 33.58 35.82 34.57 1.00 1.00
3 27 17 21.59 33.74 - - 1.00 1.00
2 35 6 13.94 25.93 28.17 26.92 1.00 1.00
3 35 8 17.13 29.12 32.48 31.98 1.00 1.00
1-1/2* 35 8 17.13 29.12 30.48 29.07 1.00 1.00
3* 35 14 26.86 38.85 42.21 41.71 1.00 1.00
*50Hz
Question and Answer IconNeed help?

Do you have a question about the Flint & Walling PB2717S303A and is the answer not in the manual?

Flint & Walling PB2717S303A Specifications

General IconGeneral
BrandFlint & Walling
ModelPB2717S303A
CategoryWater Pump
LanguageEnglish

Summary

Pressure Booster Pumps

Performance Specifications

60 Hz Models

Presents performance data for 60Hz pump models.

Single Phase Motor Data 60 HZ

Single Phase 60 Hz 3450 RPM Capacitor Start

Provides electrical data for single phase 60Hz motors.

Single Phase Motor Data 50 HZ

Single Phase 50 Hz 2850 RPM Capacitor Start

Provides electrical data for single phase 50Hz motors.

Three Phase Motor Data

Three Phase 60;50 Hz 3450;2850 RPM Capacitor Start

Details electrical specifications for three phase motors.

General Safety Information

Installation

Pump Installation

Steps for correctly installing the pump unit and foundation.

Pressure Boost Systems

Specific considerations for setting up pressure boost systems.

Wiring Procedures

Instructions and diagrams for wiring single phase and three phase motors.

Operation

Maintenance

Mechanical Seal Replacement

Detailed guide for replacing the mechanical seal assembly.

Troubleshooting Chart

Related product manuals