What to do if there is Alibi memory could not be initialized in Flintec FT-111 Accessories?
- MMitchell DurhamSep 6, 2025
If the alibi memory could not be initialized, check the alibi memory SD card, or change the main board.
What to do if there is Alibi memory could not be initialized in Flintec FT-111 Accessories?
If the alibi memory could not be initialized, check the alibi memory SD card, or change the main board.
What to do if the weight is out of power on zero range in Flintec FT-111 Accessories?
Press key to start indication without zeroing and call service.
What to do if there is Status error of load cell in Flintec FT-111?
If there is a status error of the load cell, change the load cell.
What to do if there is Wrong SD card at alibi memory in Flintec Accessories?
If the wrong SD card is used at alibi memory, order an Alibi SD card.
What to do if the load exceeds the operation range in Flintec FT-111 Accessories?
If the load exceeds the operation range, check the load and the calibration. It is also possible that the load cell or instrument is broken.
What to do if there is ADC output is not changed for the span calibration in Flintec FT-111 Accessories?
If the ADC output is not changed for the span calibration, recalibrate the scale or change the mainboard.
What to do if there is Alibi CSUM error in Flintec Accessories?
If an Alibi CSUM error occurs, check the alibi memory records. If necessary, change the Alibi memory SD card or the main board.
What to do if there is a Checksum error in Flintec FT-111 Accessories?
If a checksum error occurs, check the termination resistors and the DLC connection (RS-485 & Power supply) hardware.
What to do if Alibi memory SD card is not installed in Flintec Accessories?
If the Alibi memory SD card is not installed, disable Alibi memory if it is not required. Otherwise, check the Alibi SD card or change the mainboard.
What to do if the load cell output is decreased after loading in Flintec FT-111?
If the load cell output decreases after loading, check the load cell connections and the test weight loading. You may also need to recalibrate the scale or change the mainboard.
Brand | Flintec |
---|---|
Model | FT-111 Series |
Category | Accessories |
Language | English |
Comprehensive guide to various electrical connection options for the instrument.
Covers fulfilling data recording obligations using the alibi memory function.
Overview of the programming menu structure and parameter adjustment.
Detailed steps for performing scale calibration and adjustments.
Process for addressing digital load cells and shift adjustment methods.
Covers Modbus RTU and TCP/IP interfaces, data structures, and setup.
Details Ethernet TCP/IP interface parameters, data formats, and setup.
Information on Profibus DPV1 interface, baud rates, LEDs, and data format.
Details the Profinet interface, LEDs, parameters, and GSDML configuration.
Covers CANopen network communication, LEDs, and data format.
Details EtherNet/IP interface, LEDs, parameters, and EDS configuration.
Covers EtherCAT interface, LEDs, data format, and ESI configuration.
Details CC-Link network, LEDs, configuration, and data format.