Questions and Answers

  • H
    harrelljamieSep 12, 2025
    What to do if there is Checksum error of EPL printout format in Flintec FT-111 D Accessories?
    • M
      Mr. Terry Brown MDSep 12, 2025
      If a checksum error of EPL printout format occurs, press enter key and re-load the EPL code, or change E2ROM ( U13 ).
  • J
    Jason WattsAug 25, 2025
    What to do if the weight is too low for Flintec FT-111 D?
    • S
      shirleywarnerAug 25, 2025
      If the weight is too low, check the load, as the load cell or instrument could be broken.
  • J
    John BushAug 25, 2025
    What to do if there is a communication error between the display board and main board in Flintec Accessories?
    • C
      carlossmithAug 26, 2025
      If there is a communication error between the display board and the main board, power off the instrument and reenergize it after 30 seconds. If the issue persists, consider changing the main board.
  • J
    john08Sep 23, 2025
    What to do if The DLC is over in Flintec Accessories?
    • M
      Michael SimonSep 23, 2025
      If The DLC is over, check mechanical installation and DLC.
  • F
    Frank StrongSep 12, 2025
    What to do if there is The DLC Board is broken or not installed in Flintec FT-111 D Accessories?
    • S
      Sara ChoiSep 12, 2025
      If The DLC Board is broken or not installed, re-energize indicator or change the DLC Board.
  • A
    Alexis MarshallSep 18, 2025
    What to do if there is No regular response from load cell in Flintec FT-111 D Accessories?
    • C
      colinmurphySep 18, 2025
      If there is no regular response from the load cell, reenergize the indicator, check the DLC connection (RS-485 & Power supply), or change the load cell.
  • D
    Douglas WalkerSep 5, 2025
    What to do if the weight is out of power on zero range in Flintec FT-111 D Accessories?
    • J
      Jorge JordanSep 5, 2025
      Press key to start indication without zeroing and call service.
  • S
    Sarah MooreSep 6, 2025
    What to do if there is Alibi memory could not be initialized in Flintec Accessories?
    • R
      Richard TravisSep 6, 2025
      If the alibi memory could not be initialized, check the alibi memory SD card, or change the main board.
  • M
    Margaret WattsSep 18, 2025
    What to do if there is The address and S/N of the load cell do not match in Flintec FT-111 D?
    • M
      Mason MorrisSep 18, 2025
      If the address and S/N of the load cell do not match, check the DLC and S/N, reenergize the indicator, or readdress the DLC.
  • F
    feliciahuffAug 30, 2025
    What to do if the load cell output is decreased after loading in Flintec FT-111 D Accessories?
    • M
      Matthew ClineAug 30, 2025
      If the load cell output decreases after loading, check the load cell connections and the test weight loading. You may also need to recalibrate the scale or change the mainboard.

Summary

Safety Instructions

Installation

Electrical Connections

Detailed wiring instructions for load cells and other interfaces.

Analogue Load Cell Connection (Only FT-111)

Wiring details for connecting analogue load cells to the FT-111.

Digital Load Cell Connection (Only FT-111 D)

Wiring details for connecting digital load cells to the FT-111 D.

Ethernet TCP;IP

Configuration and pinout for the Ethernet TCP/IP interface.

EtherNET;IP

Configuration and pinout for the EtherNET/IP interface.

FT-111(D) FUNCTIONS

Alibi Memory

Details on activating and using the Alibi memory for data recording.

PROGRAMMING AND CALIBRATION

Programming and Parameters

Navigating the programming menu and modifying parameters.

Calibration

Procedures for performing scale calibration with test weights.

DIGITAL LOAD CELL (DLC)

Addressing Digital Load cells

Steps for addressing and configuring digital load cells.

DIGITAL INPUTS AND OUTPUTS

SERIAL DATA OUTPUTS

OPTIONAL COMMUNICATION

Modbus RTU and TCP;IP

Details on Modbus RTU and TCP/IP communication protocols.

Ethernet TCP;IP

Configuration parameters for the Ethernet TCP/IP interface.

Profibus DP

Information on Profibus DP interface, baud rates, and LEDs.

Profinet

Details on the Profinet interface, LEDs, and configuration.

CANopen

Information on CANopen network communication, LEDs, and data format.

EtherCAT

Information on EtherCAT interface, LEDs, and data format.

CC-Link

Details on CC-Link network communication, LEDs, and configuration.

TROUBLE SHOOTING

Flintec FT-111 D Specifications

General IconGeneral
BrandFlintec
ModelFT-111 D
CategoryAccessories
LanguageEnglish

Related product manuals