FT-111(D) Panel Weighing Indicator, Technical Manual, Rev.1.0.0, May 2019 Page 37 of 146
5.2 Advanced Functions
Programmable key
key can be programmable to fit the instrument in to your application and for your easy it. The programmable functions
are unit change, dynamic start/reset, basic peak, hold etc. Refer to sub-block 24-, page 56 to see the availabilities.
High resolution
If you press key, the weight value is displayed 10 times higher resolution until pressing the same key again. High
resolution is displayed temporarily for 5 seconds at approved scales. High resolution cannot be printed.
Unit change
If you program the key, the weight unit is changed to second unit from first unit or to first unit from second unit. The
unit change is available between kg and lb. Refer to parameters 521.
Dynamic weighing
APPLICATION: Living stock weighing, weighing of unstable load, unstable industrial weighing systems.
RELATED PARAMETERS: Sub-block 33-, page 57.
The dynamic weighing can be programmed for single weighing or continuous weighing after assigning the
programmable key for dynamic weighing. Single weighing is used for dynamic weighing of parts like living
animals; continuous dynamic weighing can be used for loads which have very high vibration like reactors having
high speed mixers, conveyors etc.
Single weighing operation:
1. Place container on the scale.
2. Press key to tare the scale.
3. Load the scale.
4. Press the dynamic weighing key to start dynamic weighing. Or dynamic weighing is started
automatically if the load is heavier than 50 divisions. Refer to parameter 331.
5. After the weighing cycle, the dynamic weight value is displayed.
6. Unload the scale or press the dynamic weighing key to reset dynamic weighing operation.
Depend on the operation type selected at parameter 331, the dynamic weighing may start automatically if the
load is heavier than minimum weight or may end after unloading the scale (refer to page 57).
Net sign correction
Some weighing of materials are done by unloading the material from the container. The net sign correction
enables always positive net weighing at loading and at unloading the material from scale by switching gross
and tare weights, if necessary. Refer to parameter 237 to enable net sign correction.
Enabled net sign correction affects the display and printed data.
Displaying
and printout
Net sign
correction
disabled
Net sign
correction
enabled
Tare
120.0 kg
30.0 kg
Gross
30.0 kg
120.0 kg
Net
- 90.0 kg
90.0 kg