EasyManua.ls Logo

Flintec FT-111 D - Key Pad

Default Icon
146 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
FT-111(D) Panel Weighing Indicator, Technical Manual, Rev.1.0.0, May 2019 Page 15 of 146
3.5 Key Pad
The keys and the key functions of FT-111 in usage are:
Programmable Function key This programmable key is set for your easy
usage in your application.
Escape Press this key to exit from any entry or from any block at programming.
Page 56, 37,
Temporary gross weight indication Press the key to read the gross weight
temporary until pressing the key.
The display returns to the normal operation automatically after 10 seconds at
approved scales.
High resolution Press the key to read the weight at high resolution. Press the
second time to return normal operation. The high resolution weight displaying is
ended automatically in 10 seconds at approved scales.
Page 37, 60
Set point entries Press this key to enter set points.
Page 84,
Memory This key is used to access the memory or to save the item
data in to the memory.
Page 84
Navigation keys These keys are used to navigate in the memories, entries and
programming.
The meanings of the navigation keys are;
Page 96
Previous parameter.
Next digit or parameter.
Increase or next block.
Decrease or previous block.
Enter into the parameter to enter data.
Save the data after entry.
Go to the next parameter.
Print By pressing this key the weight data is transferred to a printer or to a PC at
weighing.
Page 96, 89
Tare Press this key for taring the scale.
Page 35, 36, 55
Clear Clears the tare and indication returns to the gross value.
Page 36
Zeroing If the unloaded scale doesn’t show zero at gross operation, press this
key to compensate zero drift.
Page 35, 61

Table of Contents

Related product manuals