FT-111(D) Panel Weighing Indicator, Technical Manual, Rev.1.0.0, May 2019 Page 61 of 146
Disable.
± 2%
± 3%
± 20%
± 50%
Disable.
± 0,3d
± 0,5d
± 1d
± 2d
± 3d
Stability detection range.
Disable.
± 0,3d
± 0,5d
± 1d
± 2d
± 3d
± 4d
The scale is accepted as a stable to process, If the scale is stable
during this time.
0.1…. 9.9 seconds.
Minimum tare for automatic taring
Taring can be done if loading is heavier than MIN TARE.
Minimum weight to produce printout
The printout is produced if the load is heavier than MIN WEIGHT.
Tilt switch to prevent wrong weighing results in mobile scales.
(Digital Input-4)
Not used.
Normally open contact.
Normally closed contact.
SCALE BUILD
Press key or key again to enter this menu.
Press key to go to the next sub-block or press
key to go to the next main-block.
The scale unit
Select NO, g, kg, t, lb, klb, N or kN.
Single Range
2 x Multi Range
3 x Multi Range
2 x Multi Interval
3 x Multi Interval