FT-111(D) Panel Weighing Indicator, Technical Manual, Rev.1.0.0, May 2019 Page 55 of 146
[
213
KEYSOU
N
:
YES
]
Key sound
NO
YES
:
:
Disable
Enable
[
214
REFRESH
:
5
]
Display refresh rate
X
:
1...9 times/sec
[
22-
INFO DISPLAY
]
INFORMATION DISPLAY
Press key or key again to enter this menu.
Or press key to go to the next sub-block.
[
221
TIME
:
D+T
]
Information data on the right of the alphanumeric display.
NO
T
D
D+T
:
:
:
:
No clock data on the display.
Display time,
Display date,
Display date and time,
[
222
DATA
:
TARE
]
Information data on the left of the alphanumeric display.
NO
TARE
GROS
:
:
:
No data
Tare weight is displayed
Gross weight is displayed in Net
[
23-
START UP
]
START UP
Press key or key again to enter this menu.
Or press key to go to the next sub-block.
[
231
TARING
:
MULT
]
Taring.
Page 36
NO
MULT
GRO
S
:
:
:
Disabled.
Tare with key, via serial interface or via digital input.
Tare with key, via serial interface or via digital input
only at gross.
[
232
AUTO T
:
NO
]
Auto taring.
Page 36
NO
YES
:
:
Disabled.
Auto tare, if the gross load is bigger than MIN TARE
and stable.
[
233
AUTO
CLR
:
NO
]
Auto clear.
Page 36
NO
YES
:
:
Disabled.
Auto clear, if the gross load is lower than 10d.
[
234
PWR
TARE
:
NO
]
Restore Tare at power on
NO
YES
:
:
Disabled.
Tare value is saved at power off and the indication is
start in NET after switch on the instrument.