EasyManua.ls Logo

Flintec FT-111 D - PROGRAMMING AND CALIBRATION; Entering to the Programming and Calibration

Default Icon
146 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
FT-111(D) Panel Weighing Indicator, Technical Manual, Rev.1.0.0, May 2019 Page 40 of 146
Search with Alibi record number:
1. Press key after selecting NUM in parameter 813.
2. Press numerical keys to enter alibi number in the printout data and press key. You
may navigate in the alibi memory with or keys after entering alibi number.
3. The weighing data in the alibi memory is indicated on the display.
4. Press key to print this record and the previous nine weighing.
5. Press key 4 times to return operation.
Search with date:
1. Press key after selecting DATE in parameter 813.
2. Press numerical keys to enter date in the printout data and press key. The date format
entry should be as in the operation. e.g. date entry should be DDMMYY if parameter 251 is
set to DMY. You may navigate in the alibi memory with or keys after entering
the date.
3. The weighing data in the alibi memory is indicated on the display.
4. Press key to print this record and the previous nine weighing.
5. Press key 4 times to return operation.
Search with weight value:
1. Press key after selecting NET, gross or tare which is suitable in parameter 813.
2. Press numerical keys to enter weight value in the printout data and press key.
3. The alibi record is indicated on the display.
4. Press key to print this record and the previous nine weighing.
5. Press key 4 times to return operation.
Transfer all Alibi records
1. Go to the parameter [ 8-- METROLOGY ] main block in set up.
2. Press key 5 times to access parameter 814.
3. Press or keys to select PRNT and press key to start transferring.
4. Or you may stop transferring by pressing key.
About Alibi Memory
1. Go to the parameter [ 8-- METROLOGY ] main block in set up.
2. Press key 6 times to access parameter 815.
3. Press key to print alibi information.
Format Alibi Memory
Warning : Alibi memory formatting should be done by authorized person. Otherwise erasing alibi memory may
bring you undesired legal responsibility.
You may need to format alibi memory after installing the used SD card, to erase previous records before starting
usage in legal or to erase alibi memory if you don’t need previous records legally. This process runs if the
calibration switch is at programming position.
1. Go to the parameter [ 8-- METROLOGY ] main block in set up.
2. Press key 7 times to access parameter 816.
3. Select YES and press key.
4. The warning prompt [ ARE YOU SURE? ] appears on the display.
5. Press key to start formatting or Press key to escape.
6. Press key 3 times to return operation.
The empty fields are indicated as [ ------- ] and transferred as [ NO RECORD ]; and the corrupted records
are indicated as [ Error ] and transferred as [ CORRUPTED ].