EasyManua.ls Logo

FLIR 793950385753 - Page 41

FLIR 793950385753
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
FLIR CM275 USER MANUAL Document Identifier: CM275-en-US_AC
41
ACA function:
> 6A (rms) at 60.00A range for 10Hz ~ 1kHz
> 60A (rms) at 600.0A range for 10Hz ~ 1kHz
Hz function at ACA rotary switch:
> 6A (rms) for 10Hz ~ 10kHz
Table 13.4 Inrush current
Function Range Accuracy
ACA Inrush
60.00 A ±(3% + 0.3 A)
600.0 A ±(3% + 5 dgt)
Inrush current detection threshold: 0.5A for 60A range and 5.0A for 600.0A range
Overload protection: 1000 V
(rms)
, 600 A (rms).
Integration time is 100 ms.
Table 13.5 Resistance, Continuity, and Diode
Function Range Accuracy
Resistance
±(1.0% + 5 dgt)
Continuity 600.0 ±(1.0% + 5 dgt)
Diode 1.5V ±(1.5% + 5 dgt)
Overload protection: 1000 V
(rms)
.
Maximum test current: Approx. 0.1 mA.
: Approx. 1.8 V.
Maximum open circuit voltage for diode: Approx. 1.8 V.
Continuity threshold:
>
Continuity indicator: 2.7 kHz tone buzzer.
Continuity response time: <100 ms.
www.calcert.com sales@calcert.com1.888.610.7664