EasyManua.ls Logo

FLIR 793950385753 - Page 42

FLIR 793950385753
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
FLIR CM275 USER MANUAL Document Identifier: CM275-en-US_AC
42
Table 13.6 Capacitance
Function Range Accuracy
Capacitance ±(1.0% + 4 dgt)
Overload protection: 1000 V
(rms)
.
Table 13.7 Flex Clamp Adaptor Function
Function Range Accuracy
Flex (ACA)
30.00 A
±(1% + 5 dgt) 45 ~ 400Hz 300.0 A
3000 A
Additional accuracy for the Flex function is listed in the FLIR clamp adaptor User Manuals (Models
TA72_TA74).
Table 13.8 Flex Clamp Adaptor Function (Frequency)
Function Range Accuracy
Frequency (Flex)
600.0 Hz
±(0.1% + 2 dgt) 6.000 kHz
10.00 kHz
Sensitivity:
Flex function:
> 3A (rms) at 30.00A range for 10Hz ~ 1kHz
> 30A (rms) at 300.0A range for 10Hz ~ 1kHz
> 300A (rms) at 3000A range for 10Hz ~ 1kHz
Hz function at Flex rotary switch:
> 3A (rms) for 10Hz ~ 10kHz
> 6A (rms) for 10kHz ~ 60kHz
Work Lights
Color Temperature: 4000-5000°K
Beam Angle: ± 20°
Light Output: 70 lumens, minimum
Power: 0.5 Watt RMS