General IconGeneral
Energy Range (Gamma)30 keV to 3 MeV
Isotope IdentificationYes
DisplayColor LCD
Battery LifeUp to 24 hours
Ingress ProtectionIP67
Radiation DetectionGamma
Dose Rate Range0.01 µSv/h to 10 mSv/h
Weight1.5 kg
Operating Temperature-20°C to +50°C

Summary

Welcome

1.2 Safety Warnings

Essential warnings for operating the FLIR identiFINDER R200, including housing integrity and power connection safety.

Operating the identiFINDER® R200

2.6 Resetting Values to Factory Presets

Steps to reset the FLIR identiFINDER R200 to its factory default settings, including password reset.

Field Operating Guide

3.1 Powering On/Off and Checking the Instrument

Detailed guide on powering the FLIR identiFINDER R200 on/off and performing instrument checks.

3.2 Observing the Environment

How to use the FLIR identiFINDER R200 in Dose Rate Mode to observe and measure radiation in the environment.

3.3 Locating a Radiation Source

Using "Finder Mode" to locate radiation sources, including background measurement and source detection.

3.4 Identification

Using "Identify" mode to determine the specific nuclides present from a detected radiation source.

3.5 Transfer, Connection and Communication with a Computer

Methods for connecting the FLIR identiFINDER R200 to a computer for data transfer and communication.

Modes

4.1 Dose Rate

Explanation of the "Dose Rate" mode, its display, units of measure, and meter readings.

Value Sets: Thresholds

How to set warning and alarm thresholds for Dose Rate, Dose, and Sigma values.

4.2 Finder

Details on using "Finder Mode", including background measurement and control limits for source detection.

4.3 Identification

Procedure for using "Identify Mode" to determine radiation source nuclides and interpret results.

Alarms

5.1 Alarms for Radiation Levels

Setting and understanding Gamma alarms for Dose Rate, Dose Threshold, and Sigma.

5.2 Sigma Alarms

Explanation of Sigma Alarms, standard deviation, and how they relate to radiation fluctuations.

Connecting to a Local Computer

Using the Web Server

7.2 Webserver Settings

Details on configuring the FLIR identiFINDER R200 via its web interface, including device settings.

Powering the identiFINDER® R200

8.2 Charging the FLIR identiFINDER R200

Detailed procedures for charging the FLIR identiFINDER R200 battery via wall outlet or computer.

A.1 FLIR identiFINDER R200: Specifications

C : Nuclide Library