Page #46 background image
DIGOUT_1A
DIGOUT_1B
DIGOUT_2A
DIGOUT_2B
FAULT_A
FAULT_B
DIGOUT_1A
DIGOUT_1B
DIGOUT_2A
DIGOUT_2B
FAULT_A
FAULT_B
DIGITAL
POWER
DIGITAL
GROUND
A
B
DIGITAL
GROUND
DIGITAL
POWER
18-30V
0V
DIGITAL
POWER
DIGITAL
GROUND
18-30V
0V
CAMERA
POWER
CAMERA
GROUND
CAMERA
POWER
CAMERA
GROUND
DIGITAL
GROUND
CAMERA
GROUND
A B A B
10k
10k
DIGIN_1
DIGIN_2
DIGIN_GND
DIGIN_1
DIGIN_2
DIGIN_GND
FUSE
FUSE
INDICATOR
INDICATOR
DIGITAL
GROUND
TEST
DIGIN_1
CAMERA
POWER
INPUT
DIGITAL
POWER
INPUT
DIGITAL
OUTPUTS
DIGITAL
INPUTS
TEST
DIGIN_2
A/CAM TX
B/CAM RX
RTN
PROBE
RS232
RS485
A/CAM TX
B/CAM RX
RTN
RTN
PROBE
Ethernet
x8
3 VOLT
DROP
3 VOLT
DROP
JUMPER
JUMPER
JUMPER
JUMPER
JUMPER
JUMPER
JUMPER
JUMPER
18-30V
0V
Camera side
Installation side
DIGITAL
POWER 12V
REG
DIGITAL
POWER
DIGITAL
GROUND
1
2
3
1
2
3
1
2
3
1
2
3

Table of Contents

Other manuals for FLIR A50 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the FLIR A50 Series and is the answer not in the manual?

FLIR A50 Series Specifications

General IconGeneral
Product TypeThermal Imaging Camera
Thermal Sensitivity< 30 mK
Frame Rate30 Hz
Infrared Resolution464 x 348 pixels
Temperature Range-20 °C to 150 °C (-4 °F to 302 °F)
Accuracy±2°C or ±2% of reading
Video OutputGigE Vision
Power RequirementsPower over Ethernet (PoE) Class 0
Storage Temperature-40 °C to 70 °C (-40 °F to 158 °F)
HumidityIEC 60068-2-30 (95% non-condensing)
Operating Temperature-15°C to +50°C