18
Specifications
Model:
CoRe+ Max
TM
Revision:
V1
Company Info:
AddEnergie Technologies Inc.
Document revision number:
V01-2021-02-27
©2021 AddEnergie Technologies Inc. All Rights Reserved. This document
is protected by copyright laws of many countries and should not be
modified, reproduced, or distributed without the prior written consent of
AddEnergie Technologies.
Description of the charger
Output connector
Input connector
Maximum output power
Operating Temperature Range
Built-in protection
Enclosure
Shipping weight
Communication protocols
Security Standard Certification
(Pending)
Level 2, 80A charging station equipped with display and card reader.
Output connector: J-1772 compliant
Split Phase 120/240 VAC Supply or single phase 120/208 VAC
(Refer to Figure 1 and Figure 2)
Maximum configurable output power: 19.2 kW @ 240V or 16.64 kW @ 208V)
Operating Temperature Range: -40 °C to +50 °C / -40 °F to + 122 °F
Overvoltage conditions and leakage current to ground.
NEMA 4X, suitable for outdoor use.
Approximately 12.15 kg / 27 lb.
OCPP version 1.6J
CSA C22.2 No. 0-10 General Requirements – Canadian Electrical code, part II
CSA 281.2 /UL2231 Standard for safety for personnel protection systems for
electric vehicle (EV) supply circuits: Requirements for protection devices for
use in charging systems
CSA C22.2 No. 280/UL2594 (1st edition) Electric vehicle supply equipment
(EVSE)
CoRe+ Max
TM
Installation Manual