OWNER’S MANUAL
Should you the installer or owner be unfamiliar with the correct installation or
operation of this type of equipment you should contact the distributor/manufacturer
for the correct advice before proceeding with the installation or operation of this
product.
We recommend, for additional protection, the pump to be supplied from
socket outlet protected by a residual current device – RCD (also known
as an Earth Leakage Circuit Breaker – ELCB) with a maximum rated
residual current of 30mA.
AUTOJET &
MULTIMAX
®
For the installation, operation and service of
STAINLESS STEEL JET PUMPS
• Autojet60 • Autojet80 • Multimax120

Questions and Answers

  • M
    Mrs. Amy JensenAug 11, 2025
    How to fix a Flotec Autojet60 that does not operate?
    • S
      Stanley SchneiderAug 11, 2025
      If your Flotec Water Pump isn't operating and the motor isn't running, first, verify that electricity is present. Next, ensure the pump is connected properly. Finally, reset the circuit breaker, if it has been activated.
  • A
    Amy PittmanAug 17, 2025
    What to do if my Flotec Water Pump delivers no water?
    • B
      bdeanAug 17, 2025
      If your Flotec Water Pump operates but delivers no water, start by filling the pump with water. Then, reduce the suction head. Also, make the suction pipe longer, up to a maximum of 8 meters, to ensure the foot valve/strainer is submerged enough. Check the suction pipe and joints for any air leaks. Clean the suction pipe/strainer or non-return valve, if they are clogged with debris. Finally, clean the pump of any debris.
  • K
    kaitlyn10Aug 22, 2025
    Why does my Flotec Water Pump stop after a short time?
    • N
      nashedgarAug 23, 2025
      If your Flotec Water Pump stops after running for a short period because a thermal motor circuit breaker trips, check the voltage on the power supply cable leads to ensure the power supply complies with the data on the name plate. If the liquid is too thick, dilute the pumped fluid. If a solid object is blocking the impellers, contact customer assistance service.
  • T
    Thomas CooleyAug 29, 2025
    How to improve reduced performance of Flotec Autojet60?
    • P
      Philip JacksonAug 29, 2025
      If your Flotec Water Pump's performance is reduced, you should reduce the suction head. Lengthen the suction pipe if the foot valve/strainer is only partially submerged. Replace defective parts if the pump shaft seal is worn or damaged. Remove any debris and flush the pump with clean water if the pump is partially blocked with debris.
  • S
    stevenhickmanSep 4, 2025
    What to do if Flotec Autojet60 Water Pump hums and relays cut in and out?
    • U
      ufletcherSep 4, 2025
      If your Flotec Water Pump hums and the thermal relays cut in and out, clean the suction pipe and foot valve/strainer. Clean the pump by flushing it with water, removing the priming and drain plugs. If the pump still cannot start after several flushings, it must be dismantled and cleaned. Also, replace the capacitor if it is defective.