Do you have a question about the Flotec WATERPRESS INOX 1000 and is the answer not in the manual?
Power | 1000 W |
---|---|
Pump housing material | Stainless Steel |
Voltage | 230 V |
Frequency | 50 Hz |
Material | Stainless Steel |
Inlet/Outlet Size | 1" |
DANGER: Keep technical equipment out of reach of children.
DANGER: Failure to follow directions may cause electric shock.
DANGER: Failure to follow directions could cause serious risk.
WARNING: Failure to follow instructions may damage pump and/or system.
WARNING: Pump cannot be used for sea water, inflammable, corrosive, explosive or dangerous liquids.
WARNING: Verify that the electropump never runs without liquids.
DANGER: Ensure electropump is disconnected from electrical supply during installation.
WARNING: Protect electropump and pipes from bad weather or freezing conditions.
DANGER: Avoid inserting hands into pump mouth when connected to mains to prevent injury.
DANGER: System leaks can cause overheating and burns. Disconnect power and cool down.
Verify that the electropump voltage and frequency match the mains supply.
Installer must ensure the electric system is grounded in accordance with law.
Ensure a high-sensitivity circuit breaker (A =30 mA) is installed.
WARNING: Use the electropump only for applications listed on the nameplate.
WARNING: Do not operate the electropump without fluids.
WARNING: Do not run the electropump with a completely closed delivery.
DANGER: Faults can cause overheating. Avoid touching, remove power, and let cool.
Avoid humidity, rain, damp environments, and protect from inundation.
Inspect visually before use. Do not use if damaged.
Do not transport by cable. Protect cables from heat, oil, and sharp edges.
DANGER: Ensure the machine is disconnected from electric power supply before maintenance.
Possible causes: no power, motor protection tripped, defective condenser, shaft blocked, or pressure switch issue.
Possible causes: empty pump body, air inlet, high suction height.
Possible causes: incorrect power supply, blocked impellers, thick liquid, or high temperature.
Possible causes: damaged tank membrane, no compressed air, blocked foot valve.
Possible causes: low pressure switch setting or air inlet from suction pipe.