EasyManua.ls Logo

Flotec WATERPRESS INOX 1000 User Manual

Flotec WATERPRESS INOX 1000
5 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Contents
Ch. 1 Features ..........................................................................................
Ch. 2 Limitations .......................................................................................
Ch. 3 Installation .......................................................................................
Ch. 4 Electrical connections .....................................................................
Ch. 5 Starting the unit ...............................................................................
Ch. 6 Adjustment of the pressure switch .................................................
Ch. 7 Use of the pump with pre-cleaner .................................................
Ch. 8 Maintenance and troubleshooting ...................................................
Appendix Figures ............................................................................................
6
GB
Dear client,
Congratulations on your purchase of this FLOTEC product. Like all FLOTEC products, it has been developed with
the help of the latest technologies and manufactured with the most advanced electrical/electronic parts.
Take the time to read the instructions carefully before using this appliance.
Thank you!
Warnings for the safety of individuals and objects.
Carefully follow the instructions marked with the following symbols.
Warns that the failure to follow the directions given may cause electric
shock.
This sign warns the operator that the failure to follow an instruction may
damage the pump and/or the system.
DANGER
Warns that the failure to follow the directions given could cause serious
risk to individuals or objects.
DANGER
Electric shock
risk
WARNING
DANGER
Keep the technical equipment out of the reach of children!
WARNING: Read this manual carefully before installing this pump.
This sign warns the operator that the failure to follow an instruction may damage the pump and/or the system.
Carefully store this manual. If problems arise, contact the Customer Assistance Service. Please verify that the pump has
been used correctly and that the cause of the problem is not imputable to its operation.
Every electropump is carefully tested and packed during its assembly.
On receiving the pump, check that the pump has not been damaged during transportation. If the pump is damaged,
immediately inform the dealer within 8 days from the date of purchase.
Ch. 1 Features
GB
1
GB
1
GB
1
GB 2
GB 3
GB
3
GB 4
GB
4
pg. 91
BOOSTER SETS FLOTEC are suitable for domestic use, to pump clean water at constant pressure; to supply
water for domestic use from wells and cisterns; to supply water for toilets, washing machines and dish washers
and to water gardens. They can also be used for pressurisation systems to increase hydrostatic pressure.
Ch. 2 Limitations
GB
4

Other manuals for Flotec WATERPRESS INOX 1000

Question and Answer IconNeed help?

Do you have a question about the Flotec WATERPRESS INOX 1000 and is the answer not in the manual?

Flotec WATERPRESS INOX 1000 Specifications

General IconGeneral
Power1000 W
Pump housing materialStainless Steel
Voltage230 V
Frequency50 Hz
MaterialStainless Steel
Inlet/Outlet Size1"

Summary

General Safety Warnings

Keep Technical Equipment Away From Children

DANGER: Keep technical equipment out of reach of children.

Risk of Electric Shock

DANGER: Failure to follow directions may cause electric shock.

Risk to Individuals or Objects

DANGER: Failure to follow directions could cause serious risk.

Risk of Pump or System Damage

WARNING: Failure to follow instructions may damage pump and/or system.

Chapter 1 Features

Chapter 2 Limitations

Operational Precautions

Prohibited Liquids

WARNING: Pump cannot be used for sea water, inflammable, corrosive, explosive or dangerous liquids.

Dry Running Prevention

WARNING: Verify that the electropump never runs without liquids.

Chapter 3 Installation

Electrical Safety During Installation

DANGER: Ensure electropump is disconnected from electrical supply during installation.

Protect Against Weather and Freezing

WARNING: Protect electropump and pipes from bad weather or freezing conditions.

Avoid Inserting Hands

DANGER: Avoid inserting hands into pump mouth when connected to mains to prevent injury.

Chapter 4 Electrical Connections

Overheating Risk from Leaks

DANGER: System leaks can cause overheating and burns. Disconnect power and cool down.

Voltage and Frequency Verification

Verify that the electropump voltage and frequency match the mains supply.

Grounding Requirements

Installer must ensure the electric system is grounded in accordance with law.

Circuit Breaker Requirement

Ensure a high-sensitivity circuit breaker (A =30 mA) is installed.

Chapter 5 Starting the Unit

Application Use

WARNING: Use the electropump only for applications listed on the nameplate.

Prevent Dry Running

WARNING: Do not operate the electropump without fluids.

Prevent Closed Delivery

WARNING: Do not run the electropump with a completely closed delivery.

Faulty Control Device Risks

DANGER: Faults can cause overheating. Avoid touching, remove power, and let cool.

Safe Pump Start Procedure

Environment Protection

Avoid humidity, rain, damp environments, and protect from inundation.

Visual Inspection

Inspect visually before use. Do not use if damaged.

Cable Handling

Do not transport by cable. Protect cables from heat, oil, and sharp edges.

Chapter 6 Adjustment of the Pressure Switch

Chapter 7 Use of the booster set with pre-cleaner

Chapter 8 Maintenance and troubleshooting

Disconnect Power for Maintenance

DANGER: Ensure the machine is disconnected from electric power supply before maintenance.

Troubleshooting

Electropump Does Not Pump Water

Possible causes: no power, motor protection tripped, defective condenser, shaft blocked, or pressure switch issue.

Motor Runs, Pump Does Not Pump Liquid

Possible causes: empty pump body, air inlet, high suction height.

Electropump Stops Due to Thermal Trip

Possible causes: incorrect power supply, blocked impellers, thick liquid, or high temperature.

Pump Starts and Stops Frequently

Possible causes: damaged tank membrane, no compressed air, blocked foot valve.

Electropump Does Not Reach Desired Pressure

Possible causes: low pressure switch setting or air inlet from suction pipe.

Electropump Not Running Continuously

Possible causes: high pressure switch adjustment or air inlet from suction pipe.

Related product manuals