13 Instruction Manual
M1_7 clr total
Save total
Select between clear tot to clear the existing flow Grand total and save tot to keep the
existing flow Grand total or set tot to set Grand flow total to a determined start value.Press ▲
to select option required and M to continue.
M1_7b set total
00000000
This menu appears only after the set tot option has been selected in menu M1_7 clr total?.
Press ► repeatedly until cursor is under digit to be edited
Press ▲ repeatedly until desired value is displayed and M to continue.
M1_8 batch mode
Yes no
Press ▲ to select the option required and M to continue
M1_9 damping
level 0
level 0, level 1, level 2, level 3, level 4, level 5 damping settings are available
Press ▲ to select the required value and M to continue
M1_10 cutoff
2%
1%, 2%, 3%, 5% & 10% of full scale (i.e. %of max flow setting M1_2) cutoff settings available
Select the level below which the β-meter will output no flow
Press ▲ to select the required value and M to continue to Main Menu
M1_11 empty pipe
Activated/ deactivated
Select to activate or deactivate empty pipe if required
Press ▲ to select the required option and M to continue to Main Menu