TROUBLESHOOTING
Your E35 Salt Chlorine Generator has diagnostic and safety features to make it easy to maintain your system.
The
table below summarizes potential faults and their causes.
Fault Indication
Potential Causes
Remedies
No Flow
Pump turned off/disconnected or
valves
closed
Blue wire disconnected from cell
Ensure valves/pump on
Connect Blue sense wire to cell
Low salt
Salt level in pool has dropped too low
Pool water temperature is low
Cell has calcified
Cell or control has failed
Take sample of water to pool
shop and check salt level
add
salt as recommended.
Add salt and turn Salt
Chlorine Generator output
down until the water is
warmer.
Clean cell
Call for Service
Display blank
No Power to Controller
Fuse blown
Plug in controller and
ensure
main power is
available
Have a service technician
replace fuse (3 amp slow
blow)
Low/No chlorine
in
pool
Cables not connected to cell
Timer period too short
Chlorine output level too low
Filter needs backwashing
pH too high
Pool stabilizer (cyanuric acid) too low
Salt level too low
Connect cables
Increase timer period
particularly in summer
Increase chlorine output
Backwash filter
Balance pH level to 7.2 7.8
Increase Stabilizer between
30
and 50 ppm
Increase salt to above 3,200 ppm